Adhesion Evaluation of Titanium Oxides Films on 316L Stainless Steel Substrate


Article Preview

Titanium oxides films were deposited on tensile sample and vascular stents made of 316L stainless steel by unbalanced magnetron sputtering. The effects of structures, deposition temperature, Ti interlayer and thickness on the adhesion of titanium oxide films were investigated by tensile tests. The results revealed that the structure of the Ti-O films affect their adhesion dramatically. TiO film is brittle and fragile, lacking ability of deformation. Therefore its adhesion was worse than that of TiO2 film. The higher substrate temperature was helpful to improve adhesion of film, the adhesion of the TiO film deposited at 673K was better than those of the TiO films deposited at 323K and 473K. The adhesion of the TiO film with Ti interlayer was better than the one without interlayer. The introduction of Ti interlayer was beneficial to adhesion of film. The adhesion of thinner TiO2 film was better than that of thicker one. TiO2 film deposited on stents had good adhesion. After expansion, the film didn’t crack and peel off. TiO2 film has potential application on the vascular stents for improving its blood compatibility.



Key Engineering Materials (Volumes 353-358)

Edited by:

Yu Zhou, Shan-Tung Tu and Xishan Xie




Z. H. Wang et al., "Adhesion Evaluation of Titanium Oxides Films on 316L Stainless Steel Substrate", Key Engineering Materials, Vols. 353-358, pp. 2127-2130, 2007

Online since:

September 2007




[1] A. Raval, A. Choubey, C. Engineer, et al. Materials Science and Engineering A. Vol. 386 (2004), pp.331-343.

[2] M.C. Chen, H.F. Liang, Y.L. Chiu, et al. Controlled Release. Vol. 108 (2005), pp.178-189.

[3] R. Waksman. Cardiovascular radiation medicine. Vol. 3 (2002), pp.226-241.

[4] B.L. van der Hoeven, N.M.M. Pires, H.M. Warda, et al. International Journal of Cardiology. Vol. 99 (2005), pp.9-17.

[5] L. Machan. Advanced Drug Delivery Reviews. Vol. 58 (2006), pp.447-462.

[6] E. Stabile, E. Cheneau, T. Kinnaird, et al. Cardiovascular radiation medicine. Vol. 5 (2004), pp.173-176.

[7] X.H. Wang, F. Zhang, C.R. Li, et al. Surface coating & technology. Vol. 128-129 (2000), pp.36-42.

[8] I. Tsyganov, M.F. Maitz, E. Wiser. Applied Surface Science. Vol. 235 (2004), pp.156-163.

[9] N. Huang, P. Yang, Y.X. Leng, et al. Biomaterials. Vol. 24 (2003), pp.2177-2187.

[10] Y.X. Leng, J.Y. Chen, H. Sun, et al. Surface coating & technology. Vol. 176 (2004), pp.141-147.

[11] P.D. Maguire, J.A. McLaughlin, T.I.T. Okpalugo, et al. Diamond & Related Materials. Vol. 14 (2005), pp.1277-1288.

[12] B.F. Chen, J. Hwang, G.P. Yu, et al. Thin solid films. Vol. 352 (1999), pp.173-178 Fig. 3 SEM pictures of TiO2 films on expanded vascular stents.