The Contact Resistance and Arc Erosion Behavior of Separable CP-Nb-Cr/Cu-Cd Electrical Contact Material

Abstract:

Article Preview

CP-Nb-Cr/Cu-Cd electrical contact material, which contains 1.7wt.% of Cd, 0.5wt.% of CP (man-made diamond particles), 2.0 wt.% of Nb and 0.7 wt.% of Cr, was fabricated by powder metallurgy process. The contact material was installed in different ac contactors covering current range from 40 to 630A. While tested under AC-4 electrical load, the electrical contact material was worn out gradually by repeated electrical arc, and microstructure of the arc-affected surface layer changed dramatically. Mechanism of arc erosion process and contact resistance fluctuation was discussed by corresponding microstructure observation and chemical composition analysis of the surface layer. CP-Nb-Cr/Cu-Cd electrical contact material is capable to be used in 63~250A ac contactors under AC-4 working conditions.

Info:

Periodical:

Key Engineering Materials (Volumes 353-358)

Edited by:

Yu Zhou, Shan-Tung Tu and Xishan Xie

Pages:

886-889

DOI:

10.4028/www.scientific.net/KEM.353-358.886

Citation:

Y. S. Cui et al., "The Contact Resistance and Arc Erosion Behavior of Separable CP-Nb-Cr/Cu-Cd Electrical Contact Material", Key Engineering Materials, Vols. 353-358, pp. 886-889, 2007

Online since:

September 2007

Export:

Price: