Nineteen Years Review of Hydroxyapatite Ceramic Coated Hip Implants: A Clinical and Histological Evaluation

Abstract:

Article Preview

The goal of hip arthroplasty is to restore the patient to an active and pain free life for ever. Unfortunately, prosthetic implants fail because of loosening, wear or infection. This study sets out to ascertain whether or not Hydroxyapatite hip arthroplasty (HA) will produce long-lasting function of at least ten years in unselected patients of all ages and all diagnoses. Cemented implants used in hip arthroplasty often loosen after ten or more years of use. This is partly mechanical but also associated with debris disease arising from plastic wear products. Cementing techniques have been improved and the Swedish Hip Register [1] demonstrates that the revision rates have been reduced with improved cementing techniques. Revision surgery after cemented arthroplasty is difficult and may be complicated by fracture of the host bone Bioactive materials are being used to secure joint implants [2,3] and this paper presents the results of a consecutive series of hip arthroplasties carried out over a total period of over 19 years using the Furlong Hydroxyapatite Ceramic Coated hip prosthesis.[4, 5]

Info:

Periodical:

Key Engineering Materials (Volumes 361-363)

Main Theme:

Edited by:

Guy Daculsi and Pierre Layrolle

Pages:

1315-1318

Citation:

J. M. Buchanan and S. Goodfellow, "Nineteen Years Review of Hydroxyapatite Ceramic Coated Hip Implants: A Clinical and Histological Evaluation", Key Engineering Materials, Vols. 361-363, pp. 1315-1318, 2008

Online since:

November 2007

Export:

Price:

$38.00

[1] Journal of Bone and Joint Surgery - American 2000 - 2004 [Mar] 2002, Volume 84-A Supplement 2 2 The Swedish Total Hip Replacement Register Scientific Exhibit.

[2] Geesink RGT, de Groot K, Klein CPAT. Bonding of Bone to Apatite Coated Implants. J Bone Joint Surg (Br) 1988; 70-B: 17-22.

[3] McNally SA, Shepperd JAN, Mann CV, Walczak JP. The Results of twelve years use of a Hydroxyapatite-Coated Femoral Stem, J Bone Joint Surg (Br), 2000, 82-B: 378-382.

DOI: https://doi.org/10.1302/0301-620x.82b3.10114

[4] Furlong RJ, Osborn JF. Fixation of Hip Prostheses by Hydroxyapatite Coatings. J Bone Joint Surg (Br) 1991, 73-B; 741-5.

[5] Geesink RGT, Hoefnagels NHM. Six Years Results of Hydroxylapatite Coated Total Hip Replacement. J Bone Joint Surg (Br) 1992, 74-B; 74-77.

[6] Professor Archie Malcolm, Personal Communication.

[7] Sedel L, Nizard RS, Kerboull L et al. Alumina- Alumina hip replacement in patients younger than 50 years old. Clin Orthop 298: 175-183 (1994).

DOI: https://doi.org/10.1097/00003086-199401000-00023

[8] Harris H. Traumatic arthritis of the hip after dislocation and acetabular fracture: treatment by mold arthroplasty: an end result study using a new method of result evaluation. J Bone Joint Surg [Am] 1969; 51A: 737-55.

DOI: https://doi.org/10.1007/978-1-4471-5451-8_3

[9] Dr Ralf Kettner, The Unique Interface Reaction of H-AC Proceedings, Furlong Research Foundation 1995. ISBN 0 9520728 0 8 . 41-51.