Biomedical Properties of Tantalum Coatings Prepared by Multi Arc Ion-Plating

Abstract:

Article Preview

Ti-50.6 at.% Ni shape memory alloy was coated with tantalum using multi arc ion-plating technique with the aim to increase its radiopacity and biocompatibility. The surface characteristics were investigated by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The results of XPS survey spectra show that a thin oxide film are formed inside tantalum coating as a result of natural passivation of Ta in atmosphere. The hemocompatibility was evaluated in vitro by clotting time and platelet adhesion measurement. The results of our study showed that the clotting time of tantalum was higher than that of the TiNi alloys and no sign of accumulation and only slight pseudopodium was observed on the tantalum coatings, suggesting that the tantalum coatings can improve the biocompatibility of TiNi alloy.

Info:

Periodical:

Materials Science Forum (Volumes 475-479)

Main Theme:

Edited by:

Z.Y. Zhong, H. Saka, T.H. Kim, E.A. Holm, Y.F. Han and X.S. Xie

Pages:

2349-2352

Citation:

W. Cai et al., "Biomedical Properties of Tantalum Coatings Prepared by Multi Arc Ion-Plating", Materials Science Forum, Vols. 475-479, pp. 2349-2352, 2005

Online since:

January 2005

Export:

Price:

$38.00

[1] T. Duerig, A. Pelton and D. Stockel: Mater. Sci. Eng Vol. A273-275 (1999), p.149.

[2] S. Shabalovskaya: Bio-Med. Mater. Eng. Vol. 6 (1996), p.267.

[3] T. W. Duerig, D. E. Tolomea and M. Wholey: Min Invas Ther & Allied Technol Vol. 9 (2000) p.235.

[4] J. Ryhänen, E. Niemi , S. Serlo, E. Niemela, P. Sandvik, H. Pernu and T. Salo: J. Biomed. Mater. Res Vol. 6 (1997), p.451.

DOI: https://doi.org/10.1002/(sici)1097-4636(19970615)35:4<451::aid-jbm5>3.3.co;2-x

[5] D. J. Wever, A. G. Veldhuizen, J. Vries, H. J. Busscher, D. R. A. Uges and J. R. van Horn: Biomaterials Vol. 19 (1998), p.761.

DOI: https://doi.org/10.1016/s0142-9612(97)00210-x

[6] H. Randawa and P. C. Johnson: Res & Devel Vol. 2 (1987), p.173.

[7] R. Venugopalan and C. Trepanier: Min Invas Ther & Allied Technol Vol. 9 (2000), p.67.

[8] D. E. Hodgson and S. A. Smith: Proceedings of the Second International Conference on Shape Memory and Superelastic Technologies. 1997, p.461.

[9] A. Warren: Radiol Vol. (1970), p.327.

[10] H. Zitter and H. Plenk: J. Biomed. Mater. Res Vol. 21 (1987) p.881.

[11] N. Huang, P. Yang, X. Cheng: Biomaterials Vol. 19 (1998), p.771.

[12] F. Moulder, W. F. Stickle, P. E. Soblo, K. D. Bomben: Perkin-Elmer Corporation, Eden Prairie, MN, 1992, p.171 5µµµµm b 5µµµµm a Fig. 4 The platelet morphologies on the surface of the uncoated (a) and coated (b) TiNi alloys.