[1]
D. E. Bray and R. K. Stanley: Nondestructive Evaluation (CRC Press, New York 1997).
Google Scholar
[2]
M. Krause, F. Mielentz, B. Milman, W. Müller, V. Schmitz and H. Wiggenhauser: Ultrasonic imaging of concrete members using an array system, NDT & E International, vol. 34 (2001), pp.403-408.
DOI: 10.1016/s0963-8695(01)00007-x
Google Scholar
[3]
J. Johnson, O. Ömer, U. Demirci, S. Ergun, M. Karaman and P. Khuri-Yakub: Medical imaging using capacitive micromachined ultrasonic transducer arrays, Ultrasonics, vol. 40 (2002), pp.471-476.
DOI: 10.1016/s0041-624x(02)00161-0
Google Scholar
[4]
M. Akhnak, O. Martinez, L. G. Ullate and F. Montero de Expinosa: 64 Elements two-dimensional piezoelectric array for 3D imaging, Ultrasonics, vol. 40 (2002), pp.139-143.
DOI: 10.1016/s0041-624x(02)00102-6
Google Scholar
[5]
L. W. Schmerr, Jr.: Fundamentals of Ultrasonic Nondestructive Evaluation (Plenum Press, New York 1998).
Google Scholar
[6]
S. L. Wood: Visualization and modeling of 3-D structures, IEEE Engineering in Medicine and Biology magazine, vol. 11 (1992), pp.72-79.
Google Scholar
[7]
T. R. Nelson and D. H. Pretorius: Three-dimensional ultrasound imaging, Ultrasound in Med. and Biol., vol. 24, no. 9 (1998), pp.1243-1270.
DOI: 10.1016/s0301-5629(98)00043-x
Google Scholar
[8]
R. A. Robb: Three-Dimensional Biomedical Imaging (VCH Publisher Inc., New York 1995).
Google Scholar
[9]
S. Son, S. M. Song, J. Cho, J. Sung, H. Ahn and J. Lee: Three-dimensional visualization of ultrasound pulse echo data for nondestructive testing of metal structures, in Proc. 6th Far-East Conference on Nondestructive testing (2002), pp.159-614.
Google Scholar
[10]
S. M. Song, S. Son, J. Cho, J. Sung, H. Ahn and S. Jang: Ultrasonic nondestructive testing by 3-D processing of pulse-echo signal, Journal of Nondestructive Evaluation, submitted.
Google Scholar
[11]
R. C. Gonzalez and R. E. Woods: Digital Image Processing (Prentice Hall, New Jersey 2002).
Google Scholar
[12]
J. K. Udupa and H. Hung: Surface versus volume rendering: a comparative assessment, in Proc. the First Conference on Visualization in Biomedical Computing (1990), pp.83-91.
DOI: 10.1109/vbc.1990.109306
Google Scholar
[13]
C. Lin, D. Yang and Y. Chung: A marching voxels method for surface rendering of volume data, in Proc. Computer Graphics International 2001 (2001), pp.306-313.
DOI: 10.1109/cgi.2001.934688
Google Scholar
[14]
U. Tiede, K. H. Hoehne, M. Bomans, A. Pommert, M. Riemer and G. Wiebecke: Investigation of medical 3D-rendering algorithms, IEEE Computer Graphics and Applications, vol. 10 (1990), pp.41-53.
DOI: 10.1109/38.50672
Google Scholar
[15]
R. A. Robb: Biomedical Imaging, Visualization and Analysis (Wiley-Liss Inc., New York 1999).
Google Scholar
[16]
M. Levoy: Display of surfaces from volume data, IEEE Computer Graphics and Applications, vol. 8 (1988), pp.29-37.
DOI: 10.1109/38.511
Google Scholar
[17]
W. Krüger: The application of transport theory to the visualization of 3D scalar data fields", in A. Kaufman, editor, Visualization , 90 (1990), pp.273-280.
Google Scholar
[18]
P. A. Sabella: A rendering algorithm for visualizing 3D scalar fields, Computer Graphics, vol. 22, no. 4 (1988), pp.51-58.
DOI: 10.1145/378456.378476
Google Scholar
[19]
B. Girod, G. Greiner and H. Niemann: Principles of 3D Image Analysis and Synthesis (Kluwer Academic Publishers, Boston 2000).
Google Scholar
[20]
Y. Sun and D. L. Parker: Performance analysis of maximum intensity projection algorithm for display of MRA images, IEEE Trans. Med. Img., vol. 18, no. 12 (1999), pp.1154-1169.
DOI: 10.1109/42.819325
Google Scholar
[21]
S. Schreiner and R. L. Galloway: A fast maximum intensity projection algorithm for generating magnetic resonance angiograms, IEEE Trans. Med. Img., vol. 12, no. 1 (1993), pp.50-57.
DOI: 10.1109/42.222666
Google Scholar