Load Cell Ringing in High Rate Compression Tests

Article Preview

Abstract:

Mechanical test machines play an important role in providing simulation data to underpin careful analysis of high rate processes. In many cases elements of the test frame or testpiece can vibrate when subjected to a high rate force. The transducers attached to the machine frequently register this vibration superimposed on the true signal and thus may mask the signal required for analysis [1-4]. At impact all the parts of the test machine oscillate at their natural frequency (dependent on stiffness and mass). Ringing in test machines is determined by the rate at which the testpiece is deformed, the elastic characteristics of test material and resonances in components of load train anvils in compression. In the current work high rate hot compression tests are being developed to underpin best practice measurement guides on test methods for studying the dependence of strength on deformation rate and temperature, [5-7]. At higher rates of deformation ringing is observed in the transducer signals for load and displacement and this measurement note summarises the results of systematic tests to investigate this issue. A purpose built software tool was developed for analysing the time dependence of the transducer signals.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

205-210

Citation:

Online since:

September 2004

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2004 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A.J. Holzer, A technique for obtaining compressive strength at high strain rate using short load cells, Int. J. Mech. Sci., 20 (9), 1978, p.553.

DOI: 10.1016/0020-7403(78)90013-9

Google Scholar

[2] G. Laird, An investigation of ball on ball impact, Exp. Mech., 29 (3), Sept 1989, p.300.

Google Scholar

[3] J. Cain, Digital filtering of impact data, Instrumented Impact testing of Plastics and Composite Materials, ASTM STP 936, Eds S.L. Kessler, G.C. Adams, S.B. Driscoll and D.R. Ireland, Houston, Texas, 11-12 Mar, 1987, p.81.

DOI: 10.1520/stp19375s

Google Scholar

[4] D. Lui, X. Li and X. Yang, An approach for controlling oscillation in dynamic strain measurement, Trans. Non-Ferrous Met. Soc. China, 6 (2), 1996, p.144.

Google Scholar

[5] B. Roebuck, J.D. Lord, M. Brooks, M.S. Loveday, C.M. Sellars and R.W. Evans, Measuring Flow Stress in Hot Axisymmetric Compression Tests, NPL Good Practice Guide No. 3, Revised Summer (2002).

DOI: 10.1179/mht.2006.005

Google Scholar

[6] A.J. Lacey, M.S. Loveday, G.J. Mahon, B. Roebuck, C.M. Sellars and M.R. van der Winden, Measuring Flow Stress in Hot Plane Strain Compression Tests, NPL Good Practice Guide No. 27, Revised Summer (2002).

DOI: 10.1179/mht.2006.006

Google Scholar

[7] B. Roebuck, M.S. Loveday, Y. Chastel, G. Fiorucci and T. Dal Negro, High Temperature Solid Torsion Tests, NPL Good Practice Guide No. 58, May (2003).

DOI: 10.1179/mht.2006.007

Google Scholar