Development of a Non-Contact Tool Setting System for Precision Diamond Turning

Article Preview

Abstract:

Precise and efficient tool setting technique and accurate tool shape monitoring are of essential importance in ultra-precision diamond turning operation. The traditional way of tool setting are typically laborious, inefficient and rely heavily on experience. A big part of the tool setting is done by using a contact probe such as LVDT. The contact tool setting station can normally, depending on the resolution of the probes, place the tool tip to within a 1~10μm positioning accuracy. However, it is running the risk of damage the delicate tool tip and has the ambiguity introduced by contact point of tool and touch probe. The optical/non-contact way of setting the tool do have the advantage of not having to touch the tool, but its resolution is limited by the optical diffraction limit and the resolution of the CCD device used (mm/pixel). A non-contact precision tool setting system is developed and built in this study using edge-detection image processing and sub-pixel dividing techniques in conjunction with CNC controller of the precision turning machine to improve the system presently available. Depending on the sampling distance of the images, the error band gets wider when the sampling step becomes larger. In the case of 0.1μm sampling distance the obtained error band was within ±0.1μm and the results showed that tools of different shapes namely round, half-round and sharp tool could all be positioned to within an error band of ±0.1μm by using the developed tool setting system.

You might also be interested in these eBooks

Info:

Periodical:

Materials Science Forum (Volumes 505-507)

Pages:

367-372

Citation:

Online since:

January 2006

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2006 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] T. Sugan et al., (1987) Diamond turning of an aluminium alloy mirror, Annals of CIRP 36, 17-20.

Google Scholar

[2] S. To, et al., (2000) Ultra precision diamond turning of aluminium single crystals, J of Mater. Process. Technol 99, 129-134.

Google Scholar

[3] W.B. Lee, et al., (2000) An investigation of residual form error compensation in the ultra-precision machining of aspheric surface, J. Mater. Process. Technol. 99, 129-134.

DOI: 10.1016/s0924-0136(99)00403-3

Google Scholar

[4] G. O'Donnell, et al., (2001) Towards The Improvement Of Tool Condition Monitoring System In The Manufacturing Environment, J of Materials Processing Technology, 133-139.

Google Scholar

[5] M. Suchomel et al., (1995) Tool's Sharp and Position Direct Measurement by CCD Camera, 8th Int. Precision Engineering Seminar (8-IPES), May, 549-552.

Google Scholar

[6] H. Schwenke (2002) Optical Sensor For 2D And 3D Measurement Of Small Structure On Coordinate Measuring Machines, Annals Of CIRP, 51/1.

Google Scholar

[7] M.H. Chowdhury, et al., (1995).

Google Scholar

[1] 9671.

Google Scholar

[2] 0019.

Google Scholar

[1] 3957.

Google Scholar

[1] 3957.

Google Scholar

(2015).

Google Scholar

3322 Measured Error(um) Assessment Distance(um).

Google Scholar

8um Fig. 8 In the case of 0. 1µm sampling distance the obtained error band was within ±0. 1µm at the assessment distance of 50µm.

Google Scholar