Response Reduction of Two DOF Shear Structure Using TMD and TLCD by Considering Absorber Space Limit and Fluid Motion

Article Preview

Abstract:

A Combination of dynamic vibration absorbers (DVAs) consist of Tuned Mass Damper (TMD) and Tuned Liquid Column Damper (TLCD) for reducing vibration response of a two-DOF shear structure model is proposed. The absorber parameters are optimized using Genetic Algorithm (GA). The cost function is derived from the ratio between structure response and the excitation signal. The limitation in absorber space and fluid motion are considered during optimization process. The simulation results show that GA optimization procedure is effective to get the optimal absorber parameters in the case of limited absorber size and motion.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

251-256

Citation:

Online since:

June 2016

Keywords:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2016 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] M. Rusli, M. Bur and L. Son, Dynamic Vibration Absorber for Squeal Noise Suppression in Simple Model Structures, International Journal of Structural Stability and Dynamic (IJSSD). 15(5), (2015).

DOI: 10.1142/s0219455414500783

Google Scholar

[2] J.P. Den Hartog, Mechanical Vibrations: Fourth Edition, McGraw-Hill Book Company, New York, (1956).

Google Scholar

[3] M. Reiterer and F. Ziegler, Combined Seismic Activation of a SDOF-Building with a Passive TLCD Attached, 13th World Conference on Earthquake Engineering, Canada, (2004).

Google Scholar

[4] L. Son and M. Bur, Effectivity study of Double Dynamic Vibration Absorber on Building Structure due to Seismic Load, Unpublished Hibah Bersaing Research Report, Andalas University, (2013).

Google Scholar

[5] R.L. Haupt and S.E. Haupt, Practical Genetic Algorithm, John Willey & Sons, USA, (2004).

Google Scholar