The Effect of the Wall Thickness on Wear of an UHMWPE Acetabular Liner

Article Preview

Abstract:

A larger diameter of femoral head of artificial hip joint (AHJ) is commonly recommended for increasing range of motion (RoM) and for avoiding dislocation. Unfortunately, increasing that diameter will reduce the material liner thickness of the acetabular component. The behaviour of the AHJ contact system with thickness variation of the Ultra High Molecular Weight Polyethylene (UHMWPE) acetabular liner was studied numerically and experimentally. Finite element analysis was employed for calculating contact stresses and the wear volume was measured experimentally. Numerical results show higher contact stresses with decreasing liner wall thickness. Yet, the experimental results suggest that wear decreases as well with decreasing wall thickness. These findings are important in designing an optimised acetabular liner for larger RoM.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

196-200

Citation:

Online since:

August 2015

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] J. Charnley, Low Friction Arthroplasty of the Hip – Theory and Practice, Springer-Verlag, Berlin, (1979).

Google Scholar

[2] O.K. Muratoglu, C.R. Bragdon, D. O'Connor, M. Jasty, W.H. Harris, A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties, J. Arthrop. 16 (2001) 149-160.

DOI: 10.1054/arth.2001.20540

Google Scholar

[3] T.V. Swanson, D.J. Peterson, R. Seethala, R.L. Bliss, C.A. Spellmon, Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty, J. Arthrop. 25 (2010) 36-42.

DOI: 10.1016/j.arth.2010.04.032

Google Scholar

[4] E. Saputra, I.B. Anwar, R. Ismail, J. Jamari, E. van der Heide, Numerical simulation of artificial hip joint movement for Western and Japanese-style activities, J. Teknol. (Sci. & Eng. ) 66 (2014) 53-58.

DOI: 10.11113/jt.v66.2694

Google Scholar

[5] R. Ismail, E. Saputra, M. Tauviqirrahman, A.B. Legowo, I.B. Anwar, J. Jamari, Numerical study of salat movements for total hip replacement patient, App. Mech. and Mater. 493 (2014) 426-431.

DOI: 10.4028/www.scientific.net/amm.493.426

Google Scholar

[6] J. Jamari, R. Ismail, E. Saputra, S. Sugiyanto, I.B. Anwar, The effect of repeated impingement on UHMWPE material in artificial hip joint during salat activities, Adv. Mater. Res. 896 (2014) 272-275.

DOI: 10.4028/www.scientific.net/amr.896.272

Google Scholar

[7] J.C. Hermida, A. Bergula, P. Chen, C.W. Colwell Jr., D. D'Lima, Comparison of the wear rates of twenty-eight and thirty-twomillimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator, J. Bone Joint Surg. Am. 85 (2003).

DOI: 10.2106/00004623-200312000-00009

Google Scholar

[8] K.A. Shaju, S.T. Hasan, L.G. D'Souza, M. McMahon, E.L. Masterson, The 22-mm vs the 32-mm femoral head in cemented primary hip arthroplasty long-term clinical and radiological follow-up study, J. Arthrop. 20 (2005) 903-908.

DOI: 10.1016/j.arth.2005.02.005

Google Scholar

[9] F.W. Shen, Z. Lu, H.A. McKellop, Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners, Clin. Orthop. Relat. Res. 469 (2011) 395-404.

DOI: 10.1007/s11999-010-1555-6

Google Scholar