Properties and Structure of UV Light Cured CIPP Composites

Article Preview

Abstract:

One of the methods of curing (Cured-In-Place Pipe) CIPP pipes is the curing using ultraviolet (UV) light. The main difference from common CIPP types is in the structure of the liner material. In terms of material, it is a woven fiber glass fabric which is saturated with vinyl ester or polyester resin. In general, these pipes are more resistant to chemicals and achieve higher values of flexural properties. The paper focuses on the investigation of the short-term mechanical properties using three-point bending test and structure of UV cured CIPP liners. The computed tomography (CT) was used for the analysis of CIPP internal structure and composition.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

67-72

Citation:

Online since:

August 2021

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2021 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] E. Allouche, S. Alam, J. Simicevic and R. Sterling, A retrospective evaluation of cured-in-place pipe (CIPP) used in municipal gravity sewers, Ohio, (2011).

DOI: 10.1016/j.tust.2012.02.002

Google Scholar

[2] Information on https://trenchlesstechnology.com.

Google Scholar

[3] UV cured-in-place pipe for Tennessee sewer. Reinforced Plastics 56 (2012) 5.

DOI: 10.1016/s0034-3617(14)70048-7

Google Scholar

[4] Information on https://www.sehinc.com/.

Google Scholar

[5] H.W. Ji, D.D. Koo and J. Kang, Short- and long-term structural characterization of cured-in-place pipe liner with reinforced glass fiber material, International Journal of Environmental Research and Public Health 17 (2020) (2073).

DOI: 10.3390/ijerph17062073

Google Scholar

[6] H.W. Ji, S.S. Yoo, J. Kim, D.D. Koo, The mechanical properties of high strength reinforced cured-in-place pipe (CIPP) liner composites for urban water infrastructure rehabilitation, Water 10 (2018) 983.

DOI: 10.3390/w10080983

Google Scholar

[7] Information on https://www.relineuvgroup.com/reline-uv-group/de.

Google Scholar

[8] Information on http://www.iline.uk.com.

Google Scholar

[9] ČSN EN ISO 11296-4–Plastics piping systems for renovation of underground non-pressure drainage and sewerage networks–Part 4: Lining with cured-in-place pipes, Prague: Czech Standards Institute, (2018).

DOI: 10.3403/02746155u

Google Scholar