Research on the Affective Factors on Passive Film of Atmospheric Tower 304 Stainless Steel

Article Preview

Abstract:

On condition that the surface of 304 stainless steel has formed passive film, we have done research on the impact that the change of concentration of Cl- and Na+, the temperature, pH of Na+, on 304 stainless steel properties. This experiment is preceded studied with electrochemical method. The results show that along with the increase of temperature, pH improves the repairing capacity of passive film on the surface of 304 stainless steel. However, its stability decreases. Meantime, the pitting corrosion will happen become easier, when the repairing capacity of passive film and stability have been weakened because of the concentration of Na+, Cl- increases.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

190-193

Citation:

Online since:

March 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Gu Guo, Research on the Yanchang Refinery relational model of regular top system of corrosion factors [D].Xi'an: Xi'an Shiyou University, 2008. In Chinese.

Google Scholar

[2] Zhou Bensheng, Corrosion and protection in industry water cooling system. (Chemical Industry Press, China 1993), In Chinese.

Google Scholar

[3] Zhan Bolin, Zhu Youlan, Yang Zhuo, etc.Materials Review Vol.20(2006), p.79, In Chinese.

Google Scholar

[4] Zhou Lixin, Cheng Jiang, Yang Zhuoru, Corrosion Science and Protect Technology Vol.16(2004), p.375, In Chinese.

Google Scholar