A Comparative Study on the Effect of Air Gap on Sound Transmission Loss Provided by Double Glazed Panels

Article Preview

Abstract:

This paper presents an assessment for the airborne sound insulation provided by double glazed panels. The glazed panels were glass, acrylic and polycarbonate with a thickness of 4 mm. The panels were tested for 10 mm, 20 mm and 30 mm air gap thicknesses. The experiments were conducted in a transmission loss facility consisting of semi anechoic and reverberation chambers complying with International Standards ISO 140-1 and ISO 140-3. The panels were subjected to airborne sound. Glass, acrylic and polycarbonate panel absorb noise most effectively above 500 Hz with the absorption peaks at 1000 Hz. The single number sound reduction index (RW) for glass, acrylic and polycarbonate as double layers with air gap were evaluated. The results showed that the glass has higher RW for all air gaps and the results were 40.5 dB, 37.7 dB and 37.4 dB, respectively. This could be attributed mainly to the material density which is higher for the glass.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

242-246

Citation:

Online since:

April 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Q. Mao and S. Pietrzko: Applied Acoustics Vol. 71 (2010), p.32.

Google Scholar

[2] B. Naticchia and A. Carbonari: Building and Environment Vol. 42 (2007), p.2785.

Google Scholar

[3] A. Tadeu, A. Pereira., L. Godinho and J. Antonio: Applied Acoustics Vol. 68 (2007), p.17.

Google Scholar

[4] H. Yu, G. Yao, X. Wang, B. Li, Y. Yin and K. Liu: Transactions of Nonferrous Metals Society of China Vol. 17 (2007), p.93.

Google Scholar

[5] J.D. Irwin and E.R. Graf: Industrial Noise and Vibration Control (Prentice-Hall, New Jersey 1979).

Google Scholar

[6] A. Tadeu, J. Antonio and D. Mateus: Applied Acoustics Vol. 65 (2004), p.15.

Google Scholar