Research on Longitudinal Seismic Calculation Theory of Single-Story Factory Building

Article Preview

Abstract:

Regarding the distribution modes of longitudinal horizontal seismic forces of single-story factory building with no purlin concrete roof, there are conflicts between Sections 9.8.1 and 5.2.6 in the Seismic Design of Buildings GB50011-2010[1]. We suggested distributing the longitudinal seismic forces according to the proportion of the gravity loads on the subordinate areas of the lateral force components. We recommended replacing clause 1 of section 9.1.8 with “Don’t consider the effective stiffness of the enclosure walls or the partition walls”. Then for the example in Single-story Factory building Design Examples, we calculated the longitudinal seismic forces with two methods, and proved the our recommended method was correct.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2471-2477

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GB50011-2010, Seismic Design of Building, China Building Industry Press, China 2010 (In Chinese)

Google Scholar

[2] 09SG117-1, Single-story Factory building Design Examples (I), China Institute of Building Standard Design and Research (In Chinese)

Google Scholar

[3] 09J201-1, Flat Roof Building Structure (I), China Institute of Building Standard Design and Research (In Chinese)

Google Scholar

[4] Building Aseismic Design Manual (II), China Architecture and Building Press, China 2002 (In Chinese)

Google Scholar