Analysis of Storey Damage Effect Factors of SRC Frame-RC Core Tube Hybrid Structure under Cyclic Loading

Article Preview

Abstract:

Based on the general finite-element software ABAQUS, the FE model of 30-story SRC frame-RC core tube hybrid structure is built up. The maximum story drift angle of the structure under cyclic loading can effectively characterize the changes in storey damage. With the new achievements on damage effect factors, the relation between storey damage and component damage of various types and influence of the main design parameters on the storey damage law are analyzed. It is found that storey damage degree is more serious with the increase of stiffness character value and shear wall depth-thickness ratio, but the effects of both of them are gradually weakened and the change range of it is really small. Research will provide theoretical support on the building of hybrid structure damage model under earthquake excitation.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

52-55

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Powell GH, Allahabadi R. Seismic damage prediction by deterministic method: concept and procedures [J]. Earthquake Engineering and Structural Dynamics, 1988, Vol.16: 719-734.

DOI: 10.1002/eqe.4290160507

Google Scholar

[2] Wang M L, Shah S P. Reinforced concrete hysteresis model based on the damage concept [J]. Earthquake Engineering and Structural Dynamics, 1987, 15(8): 993-1003.

DOI: 10.1002/eqe.4290150806

Google Scholar

[3] Qing-lin Tao: submitted to Xi'an University of Architecture and Technology (2011). (in Chinese)

Google Scholar

[4] Qing-xuan Shi. Xing-wen Lang. Tall Building Structural Design [M]. Beijing: Science Press, (2006)

Google Scholar