Settlement and Stress Monitoring System of Urban Buried Gas Pipeline

Article Preview

Abstract:

The ground settlement caused by high-rise buildings is prominent increasingly with the rapid development of city construction, and will have negative influence on the surrounding gas pipelines. In this paper, an on-site monitoring system for settlement and stress-strain of buried gas pipeline is established, located in the neighboring area of Shanghai Center Tower, which is being built and will be the tallest building in china. The continuous online, real-time monitoring of stress changes and pipeline settlement can be realized. With the system of GPRS automatically data acquisition and wireless remote transmissions are achieved. Field test testify the effectiveness of the system, also shows that significant settlement and strain exist in the test pipe, and long-time monitoring and analysis is needed

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2464-2467

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Xinhua Chen, Qingshan Feng, Biyuan Shui. The Development and Challenges of Pipeline Failure Analysis in China. [C] 7th International Pipeline Conference, Canada,2008,473-477.

DOI: 10.1115/ipc2008-64503

Google Scholar

[2] Huang Xiaomei, Peng Shini, Yang Junjie, etc. Investigation and analysis on failure of gas pipeline in typical domestic cities. [J] GAS & HEAT.2010, 30(9), A26-A29.

Google Scholar

[3] Chen Zhengsong, Luo Zhicai, Li Qiong. Analysis of cause of land subsidence in shanghai.[J] Journal of Geodesy and Geodynamics.2009,29(8)90-94.

Google Scholar

[4] Lu Yan, Li Qinfen, Guo Zhongyang, etc. Automatical measurement of shanghai subsidence and information system[J]. Journal of East China Normal University, 2002, 4(12), 63-68.

Google Scholar

[5] Yan Jianguo, Chen Zhengsong, Luo Zhicai,etc.Analysis and prediction of land subsidence in shanghai based AR model.[J] Journal of Geodesy and Geodynamics.2009,29(5)121-124,128.

Google Scholar

[6] Liu Lanlan. Stress Analysis and Experimental Study on Natural Gas Pipeline under Uneven Settlement.[D] South China University of Technology, Guangzhou, China.2010.

Google Scholar

[7] Gong Aimin, FU Shuyan, Huang Haiyan.The Application of ANSYS in filled conduit analysis [J]. Journal of Anhui Institute of Architecture& Industry.2004, 12(5), 51-55.

Google Scholar

[8] WANG Kuichang, JIAO Wenling, PEI Yi. Influence of High-rise Building Settlement on Gas Service Pipe and Compensation Measure [J]. GAS & HEAT. 2006, 26(8), 26-27

Google Scholar

[9] Zhang Ruyi.Experimental Stress Analysis[M].China Machine Press,Beijing,(1995)

Google Scholar