The Experimental Research on Beijing Subway Air-Conditioning System Energy-Saving

Article Preview

Abstract:

The subway is the major means of transportation in Beijing, and it also takes huge energy consumption. Now the consumption of a subway station is 9500 kWh every day, and the proportion of the air-conditioning system energy dissipation is about 64%, in which, a big part of that can be saved down to save and make full use of the energy. The key to the air-conditioning system energy saving is to put forward reasonable energy-saving schemes and feasible method. In this paper, with a subway station in Beijing as a test location,the measurement and data analysis are carried out, and the schemes put forward for energy conservation and emission reduction in subway air- conditioning system.