Isolation on the Top of Columns of a Building Analysis Based on ETABS

Article Preview

Abstract:

Taking a practical five-story frame-structure with opening floor as background, the finite element analysis software ETABS is used to perform analysis of the first-floor isolation. Time-history analysis for the structures showed that, vibration reduction effect of the superstructure is obvious under 7 degree earthquakes. The substructure (isolated columns) is still in elastic deformation stage under 7 degree rare earthquakes, which proves that isolation technology on the top of columns can improve the seismic behavior of the first-floor weak frame-structure. Meanwhile, mechanical analyses and seismic design of the isolated columns are performed. The results indicated that rational design ensures the structure’s seismic safety.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1994-2000

Citation:

Online since:

May 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Lu Wei-dong,Lan Zong-jian, Liu Wei-qing.Design Method of Damped Bracings to Control the Structure with Weak Story [J].Earthquake Resistant Engineering and Retrofitting, 2011, 33 (2) 57-62.(In Chinese)

Google Scholar

[2] Qi Ai. State-of-the-art of story isolation system [J]. Earthquake Engineering and Engineering Vibration, 2004, 24(6): 114-120. (In Chinese)

Google Scholar

[3] Huang Xiangyun.Theoretical and Experimental Investigation on Mid-Story Seismic Isolation and Reduction Structures [D], Xi'an:College of Civil Engineering, 2008, 6.(In Chinese)

Google Scholar

[4] CHANG K C,HWANH J S, CHAN T C, et al. Application, R&D and Design rules for Seismic Isolation and Energy Dissipation Systems for Buildings and Bridges in Taiwan [C]//10th word conference on Seismic Isolation, Dissipation and Active VIBRATIONS Conteol of Structures, Isolanbul, [s.n.].2007, May28-31.

DOI: 10.37153/2686-7974-2019-16-267-277

Google Scholar

[5] MO Y L,CHANG Y F. Application of base isolation concept to soft first story buildings[J]. Computers & Structures, 1995, 55 (5) : 883-896.

DOI: 10.1016/0045-7949(94)00433-4

Google Scholar

[6] MA Changfei, TAN Ping, ZHANG Yahui, ZHOU Fulin. Dynamic responses analysis of structures with isolators on the top of the columns considering P-Δ effects[J]. China Civil Engineering Journal, Vol. 43, 2010: 230-234. (In Chinese)

Google Scholar

[7] Building Aseismic Design Codes (50011-2001). Beijing. China Architecture & Building Press, 2008. (In Chinese)

Google Scholar

[8] WU Ying-xiong, Qi Ai, Yan Xue-yuan.Performance Analysis of Isolation on the Top of Columns for First-floor Weak Frame-structure [J].Journal of Nanchang University(Engineering & Technology Edition) , 2011, 33 (4) 365-369.

Google Scholar

[9] CECS 126: Technical Specification for Seismic-Isolation with Laminated Rubber Beating Isolators[S].Beijing: China Association for Engineering Construction Standardization. (2001)

Google Scholar