Analysis and Summary of Characteristics of Confined Concrete

Article Preview

Abstract:

Characteristics and constraint mechanism of concrete confined by ties,concrete filled steel tube,FRP-strengthened concrete were summed up in this paper,and unified bearing capacity model for confined concrete was also introduced,then several new kinds of confined concrete forms were outlined,finally the development and application of confined concrete were prospected.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

330-335

Citation:

Online since:

May 2012

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Guo Zhenhai, Shi Xudong. Reinforced concrete theory and analysis. Beijing: Tsinghua University press, 2003.

Google Scholar

[2] Han Lin-hai, Zhong Shantong. Mechanics of concrete filled steel tubes. Dalian: Dalian University Science Press, 1996.

Google Scholar

[3] Zhou Wenfeng, Lu Ying. Confined concrete literature review. Sichuan Building Science, 2007, 33(3): 144-146.

Google Scholar

[4] HU Bo, WANG Jiangu Research Status and Prospects of FRP-confined Concrete Columns. Journal of Architecture and Civil Engineering, 2009, 26(3): 96-103.

Google Scholar

[5] Han Linhai, Characters and development of concrete filled steel tubes.Industrial construction. 1998, 29(10): 1-5.

Google Scholar

[6] Shi Qingxuan, Hou Wei. Development and prospects of hoop reinforcement confined concrete. Journal of Building Structure. 2010. Supplementary Issue 2: 109-114.

Google Scholar

[7] ASCCS Seminar Report. Concrete Filled Steel Tubes-A Comparison of International Codes and Practices, Innsbruck, Sep, 1997.

Google Scholar

[8] Si Bingjun, Sun Zhiguo, et. al.Review of studies on the seismic behavior of high strength concrete columns. China civil engineering journal. 2009. 26(4): 1-9.

Google Scholar

[9] Yu Feng,Niu Di-tao, WU Ping. Study on behavior of confined concrete. Concrete, 2006.6: 15-17.

Google Scholar

[10] Zhou Xuhong, ZHANG Sumei, LIU Jiepen. Seismic behavior of steel tube confined reinforced concrete (RC) beam-columns. Journal of Building Structures. 2008, (29)5:75-84.

Google Scholar

[11] Cao Xinming, Xiao Changan, Xiao Jianchun, et al. Analysis of regional confined concrete. Earthquake engineering and reinforcement, 2008, 30(5): 112-115.

Google Scholar

[12] Yin Yanliang, Weng Zhengqiang, Wang Ruizhen, et al. New five spirals SRC column of repeated load seismic test. Science in China series E: Science and technology, 2008, 38(9): 1414-1439.

Google Scholar

[13] Tao Zhong.Yu Qing Summary of-state-of-the art of FRP-confined concrete columns. Industrial construction. 2005, 35(9): 1-5.

Google Scholar

[14] Qian Jiaru, Liu Mingxue. Experiment of FRP-concrete-steel double-skin tubular long columns under axial compressive load. Concrete, 2006(9): 31―34.

Google Scholar

[15] Wang Yongsuo. Pan Jinglong, Experimental study on confined concrete wound with steel cable under axial compression. Industrial construction. 2007, 37(1): 104-106.

Google Scholar

[16] Yu Feng Niu Ditao PVC-FRP tube concrete structure practical applications can be Do research. Building science, 2007, 23 (11): 102-104.

Google Scholar