Airside Pressure Drop Mechanism of Automobile Air-Conditioner Evaporator Plating with Hydrophilic Film
Abstract:
A mathematical model of airside pressure drop was established, and calculations were conducted respectively under dry condition and wet condition for evaporators with hydrophilic treatment and without hydrophilic treatment. Experimental results demonstrate the proposed model. The results reveal a significant improvement of hydrophilic treatment, and air resistance drops to 53% when relative humidity is 50%, while it drops to 50% when relative humidity is 90%.