Discussion on the Design of Freezing Dehumidification-Based Radiant Air-Conditioning System

Article Preview

Abstract:

For the purpose of realizing non-dewfall condition of the radiant panels, low energy consumption and nice comfort of the freezing dehumidification-based radiant air-conditioning system, the design temperature and humidity of the room were figured out according to the mean comfort index of human body during the design. And in order to lower the energy consumption, the necessity of the reasonable load allocation between the dehumidification unit and the radiant unit was discussed by means of the calculation with the quasi heat-humidity-ratio line. As a result, much more precise design parameters were acquired through the approximation calculation. And it was proven to be a good design method by applying these parameters to the design of the reading rooms of the library. In the design example of the reading room, the load ratio between the dehumidification unit and the radiant unit was 48 to 52, and the recirculation air flow rate of the dehumidification unit was not less than 36.8% of the total air rate of the room.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

4274-4279

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Meng Zhang, Li Ma. Summer experimental research of new ceiling radiant cooling panel. Building energy and environment, 2010, 29(6):27-31(In Chinese)

Google Scholar

[2] Yang Wang. Energy Saving of Radiation Cooling System. Building energy and environment, 2010.29(3)71-74(In Chinese)

Google Scholar

[3] Baolian Niu, Qianqian Song, Xueying Xia, et al. Energy-saving refrigeration and dehumidification unit on radiant cooling and its energy-consumption analysis. Journal of Nanjing Normal University, 2009, 9(3) 39-41(In Chinese)

Google Scholar

[4] Qing He, Jinming Shen, Qingyun Shou, et al. Discussion on condensation of radiant cooling system combined with DOAS. HV&AC, 2008, 38(6) 159-162(In Chinese)

Google Scholar

[5] Xuelai Liu. Dynamic models and experimental study on capillary grating plane air-conditioning system. China University of petroleum, 2011(In Chinese)

Google Scholar

[6] Mcintyre. Indoor climate. London Applied science publisher, (1980)

Google Scholar

[7] Xiang Huang. Air conditioning engineering. Beijing Mechanical industry press, 2005(In Chinese)

Google Scholar