Evaluation of the Influence of One Air Circulation System on LGS House Indoor Thermal Environment

Article Preview

Abstract:

Basing on 3 dimensional simulation of Airpak software, it studied the indoor thermal environment characteristics and influence factor of LGS house which provided with one air circulation system. It investigated the indoor air flow velocity field, temperature field, air age distribution and PMV-PPD distribution, and completed prediction and evaluation for air flow organization and air quality. The study shows that this air circulation system improves the air flow velocity and temperature distribution of LGS house indoor, provided a good thermal environment and air exchanging effect for indoor with low energy consumption, this has a significant meaning for improving comfort level of LGS house on the basis of meeting green energy saving.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

4343-4348

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Haifeng Gao. Overview of LGS Residential System[J]. Housing Science, No.11(2010), P.21-23. (in Chinese)

Google Scholar

[2] Xiaoyan Zhou, Yukun Hua. Evaluate of the heat-conducting property of OSB wallboard[J]. Scientia silvae sinicae, No.4(2000), P.59-66. (in Chinese)

Google Scholar

[3] Xuancai Xu. Residential Building Energy Conservation Testing Standards implementation guide[M]. China Architecture Press, (2010). (in Chinese)

Google Scholar

[4] Bing Zhao, Xianting Li, Qisen Yan. Simulation of indoor air flow in ventilated room by zeroequation turbulence model[J]. Journal of Tsinghua University(Science and Technology), No.10(2001), P.112-116. (in Chinese)

Google Scholar

[5] Qingyan Chen, Weiran XU. A zero-equation turbulence model for indoor air flow simulation[J]. Energy and Building, No.28(1998), P.137-144.

DOI: 10.1016/s0378-7788(98)00020-6

Google Scholar

[6] Zhao Bin, Li Xianting, Yan Qisen. A simplified system for indoor airflow simulation [J].Building and Environment, No.4(2003), P.543-552.

DOI: 10.1016/s0360-1323(02)00182-8

Google Scholar

[7] Shouyuan Huang, Yijun Zhang, Peiwen Shen, Jie Zhang. Numerical Prediction and Evaluation of the Thermal Environment in Air-conditioned Office Based on the PMV-PPD and Air Age[J]. Refrigeration & Air Conditioning, No.6(2010), P.81. (in Chinese)

Google Scholar

[8] Damin Zhuang, Xiugan Yuan. Numerical solution of age of air[J]. Journal of beijing university of aeronautics and astronautics, No.5(1997), P.565-570. (in Chinese)

Google Scholar

[9] Shuzo Murakami, Qingyu Zhu. CFD and architectural environment design[M]. China Architecture Press, (2007). (in Chinese)

Google Scholar