Experimental Research on the Effects of Pipe Diameter on Axial Compression Properties of GFRP Tubes Reinforced Concrete Column

Article Preview

Abstract:

Through the axial compression experiment of 9 GFRP tubes reinforced concrete columns, this paper analyzes the failure mode and loading-strain curves under different pipe diameter, and compares bearing capacity between the experimental data with FRP reinforced concrete and the calculated value without GFRP tubes reinforced concrete. he results show that the bearing capacity and ductility of GFRP tubes reinforced concrete column have improved, because of the restriction effect of FRP tubes. The confining ability of FRP tubes on concrete reduced for a certain thickness GFRP tubes constraint concrete short column, while the pipe diameter is increasing.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

972-977

Citation:

Online since:

October 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2012 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Watanable K, Nakamura H, Honda T, Toyoshima M, Iso M, Fujimaki T, et al., Confinement effect of FRP sheet on strength and ductility of concrete cylinders under uniaxial compression. In: Non-Metallic(FRP) Reinforcement Concrete Structures, Proceedings of the Third International Symposium, vol. 1.

DOI: 10.1201/9781482271621-56

Google Scholar

[2] Xiao Y, Wu H. Compressive behavior of concrete confined by carbon fiber composite jackets. J Mater Civ Eng ASCE 2000; 12(2): 139-46.

DOI: 10.1061/(asce)0899-1561(2000)12:2(139)

Google Scholar

[3] Fam Alnir Z, H Rizkalla. Sami. Behavior of Axially Loaded Conerete-Filled Cireular Fiber-Reinforeed Polymer Tubes[J]. ACI Struetural Journal, 2001, 98(3): 280-289.

DOI: 10.14359/10217

Google Scholar

[4] Fam Amir, Rizkalla Sami. Large scale testing andanalysis of hybrid coneret/ eomposite tubes for cireular beam-column applieations[J]. Construetion and Building Materials, 2003, 17: 507-516.

DOI: 10.1016/s0950-0618(03)00048-5

Google Scholar

[5] Manda1S,HoskinA,FajnA. Infiuence of Conerete Strength on Confinement Effeetiveness of Fiber-Reinforeed Polymer Cireular Jaekets[J]. ACI Struetural Journal, 2005, 102(3): 383-391.

Google Scholar

[6] Peng Qian, Peng Feng, Lieping Ye. Experimental study of axial compression of GFRP tube reinforced concrete [J]. Tian jing university Journal, 2007, 40(l): 19-23. In Chinese.

Google Scholar

[7] Jie Li, YuanDe Xue, WenXiao Li. Nonlinear whole process analysis of bending members on GFRP-tube concrete composite structure[J] Glass Fiber Reinforced Composite, 2006, (3): 7-1. In Chinese.

Google Scholar