The Influence of Wall Structures to Air Conditioner Energy Consumption Based on the Characteristics of Intermittent and Loculose Energy Use

Article Preview

Abstract:

In some areas like south of China, energy is used in part time of the 24 hours and part space of the buildings, that is the characteristics of intermittent and loculose energy use. The energy consumption of the air conditioner can be calculated from the transient state with the help of numerical computing method. Among different wall configurations of self-insulation, internal insulation and external insulation walls, it shows that self-insulation and internal insulation walls performs better than external insulation walls in energy saving. The energy stored by walls which account for the most part of the energy consumption can be sharply reduced in the configurations of self-insulation, internal insulation walls.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2656-2661

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yi Jiang, Technology and application of low energy consumption construction, China Architecture and Building Press, Beijing, 2005. In Chinese.

Google Scholar

[2] Hong Zheng, Thermal insulation and energy conservation analysis of the small concrete hollow block wall in hot summer and cold winter zone, D. Zhejiang University, 2006. In Chinese.

Google Scholar

[3] Xiaoqian Qian, Yaotai Zhu, Basic research on the building energy consumption base on the intermittent and local energy use characteristics, J. China civil engineering journal, Vol. 43(2010) 392-399. In Chinese.

Google Scholar

[4] Energy efficiency building committee of China construction association, Building energy-saving technology, China Planning Press, Beijing, 1996. In Chinese.

Google Scholar

[5] M.Ozel,K. Pihtili,Optimum location and distribution of insulation layers on building walls with various orientations,building and environment 42(2007):3051-3059.

DOI: 10.1016/j.buildenv.2006.07.025

Google Scholar

[6] Youming Chen, Shengwei Wang, New methods on unsteady heat transfer analysis of building envelop, Science Press, Beijing, 2004. In Chinese.

Google Scholar

[7] Sami A. Al-Sanea, M. F. Zedan, Effect of insulation location on initial transient thermal response of building walls., journal of building physics 24(2001): 275-300.

DOI: 10.1106/07e7-fgcj-mff7-974w

Google Scholar