Analysis on Dynamic Failure Behaviors of Steel Double-Layer Latticed Cylindrical Shells with Three Circle Centers Used in a Gymnasium

Article Preview

Abstract:

In this paper, the elasto-plastic dynamic analysis on dynamic failure behaviors of steel double-layer latticed cylindrical shells with three circle centers used in a gymnasium is carried out under EL-centro wave with SAP2000, and the appraisal results on their anti-failure performances are presented under strong earthquake action based on the plastic-hinge theory. In the analyses, the geometric and material nonlinear effects are considered simultaneously based on the plastic-hinge theory. The plastic development level of the rod, the deformed shape and the failure type and the ductility are estimated by plastic hinge principle. The results show that the failure model of the structure under the earthquake wave action is complicated. Firstly the middle of the lower chord destroyed due to lack of tensile strength, then the stiffness of the integral structure degenerated, and ultimately lost its bearing capacity. Therefore, this structure has a high bearing capacity and good ductility.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

706-709

Citation:

Online since:

December 2012

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] H.W. Li, H.S. Zhao, Y.J. Zhao: Study on Planning for the Indoor-earthquake-shelter in City and Town. (Advanced Science Letters), USA, 2011,Vol. 4, p.2654–2665.J. Clerk Maxwell, A Treatise on Electricity and Magnetism, 3rd ed., vol. 2. Oxford: Clarendon, 1892, p.68–73.

DOI: 10.1166/asl.2011.1755

Google Scholar

[2] Civil King Software Technology Co., Ltd. China institute of Building Standard Design & Research. Usage Guide to Structure Analysis Program SAP2000 Chinese Edition [CP] (China communications press, China, 2006),p.460.

Google Scholar

[3] JGJ7-91(1991 edition) Code for grid structure design and construction

Google Scholar

[4] GB50011-2010(2010 edition) Code for seismic design of buildings[S]. (China architecture & building press, Beijing, 2010).M. Young, The Technical Writer's Handbook. Mill Valley, CA: University Science, 1989.

Google Scholar

[5] FEM 356 The Seismic Rehabilitation of Buildings[S]. Federal Emergency Management Agency,2000.

Google Scholar

[6] S.S. Zhao and C. Xin: Dynamic stability of grid structure [M] (Beijing, Science Press, 1999)

Google Scholar

[7] H.W. Li, J.X. Li, F. Zhi, F. Ma and D.Q. Qin: Proceedings of the 6th International Conference on Computation of Shell and Spatial Structures IASS-IACM (Cornell University, Ithaca, NY, USA, May 28-31, 2008).

DOI: 10.1016/j.engstruct.2007.07.002

Google Scholar