On Computing Leakage Flow of Plunger Pair in Radial-Plunger Pump

Article Preview

Abstract:

A new radial plunger pump is given which is installed with roller between plunger and stator, the roller is purely rolling on the inner face of stator, reducing the friction force and effectively avoiding the combustion of friction pair in working orde. When viscosity varies with pressure and temperature, hydraulic pressure and cutting flow caused by plunger moving in the plunger auxiliary of a new radial-plunger pump, the computing formula of annular gap is corrected here, which provide a theoretical support for developing a high efficient radial-plunger pump.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

35-40

Citation:

Online since:

August 2010

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2010 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chen Yansheng: Theory and Design of Static Pressure Supporting. [M] National Defense Publishing House. (1980).

Google Scholar

[2] Sheng Shenchao: Hydraulic Hydrodynamics. [M] Beijing: Machine Industry Publishing House. (1980).

Google Scholar

[3] Hook, C.J.: The effect of centrifugal load and ball friction on the lubrication of slippers in axial piston pumps, 6th inter, Fluid Power Symposium, April, 1989, pp.85-102.

Google Scholar

[4] Hu Xinhua: Research on Spherical Singe Pair of Static Pressure Supporting in Axial Plunger Pump. 2003. 5.

Google Scholar

[5] Xu Yaoming: design of friction pair between oil film theory and hydraulic pump. press of engineering industry, 1987, pp.108-255.

Google Scholar

[6] Sheng Jingchao: fluid mechanics of hydranlic, press of engineering industry, 1980, pp.71-97.

Google Scholar

[7] Xu Yaoming: Oil film Theory and Design of Friction Pair of Hydraulic Pump and Motor. [M] Beijing: Machine Industry Publishing House. (1987).

Google Scholar