Investigation on the Factors Affecting Corrosion of Tertiary-Treated Municipal Wastewater

Article Preview

Abstract:

Tertiary treatment of municipal wastewater is necessary to reduce its scaling potential for using as makeup water of circulating cooling systems. In this study the corrosivity and the factors affecting corrosion of municipal wastewater tertiary-treated by nanofiltration membrane process were assessed by weight-loss method. The results show that concentration of salt ions such as Ca2+, Mg2+, Cl- and SO42- has a significant effect on corrosivity to carbon steel. Certain quantity of calcium and magnesium ions could inhibit the corrosion of carbon steel, however, chlorine and sulfate ions could accelerate the corrosion of carbon steel. The corrosion inhibition effect of three inhibitors (PC-604, RP-101 and poly epoxy succinate (PESA)) in tertiary-treated municipal wastewater on the carbon steel was evaluated. PC-604 had the best corrosion inhibitor effect and the lowest dosage. This research has guiding significance for using tertiary-treated municipal wastewater as makeup water of circulating cooling systems.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1222-1226

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S. H. Chien, M. K. Hsieh, D. A. Dzombak, R. D. Vidic:Preprints of Extended Abstracts Presented at the ACS National Meeting 48(2008), pp.1092-1098.

Google Scholar

[2] M.K. Hsieh, H. Li, S.H. Chien, J.D. Monnell, I. Chowdhury, D.A. Dzombak, R.D. Vidic: Water Environ. Res., vol. 82 (2010), pp.2346-2356.

DOI: 10.2175/106143010x12681059117094

Google Scholar

[3] M.R. Choudhury, M.K. Hsieh, R.D. Vidic, D.A. Dzombak: Corros. Sci., vol. 61 (2012), pp.231-241.

Google Scholar

[4] Metcalf, Eddy, G. Tchobanoglous, F.L. Burton, H.D. Stensel: Waste water Engineering: Treatment and Reuse, fourth Ed., McGraw Hill, Education, (2003).

Google Scholar

[5] D. Strmcnik, M. Gaberšcek, B. Pihlar, D. Kocar, J. Jamnik: J. Electrochem. Soc., vol. 156 (2009), pp.222-229.

Google Scholar

[6] S. Gur-Reznik, I . Katz C.G. Dosoretz: Water Res., vol. 42( 2008), p.1595–1605.

Google Scholar

[7] M. Fababuj-Roger, J.A. Mendoza-Roca, M.V. Galiana-Aleixandre, A. Bes-Piá, B. Cuartas-Uribe, A. Iborra-Clar: Desalination, vol. 204 (2007), pp.219-226.

DOI: 10.1016/j.desal.2006.02.032

Google Scholar

[8] M. Vourch, B. Balannec, B. Chaufer, G. Dorange: Desalination, vol. 219 (2008), pp.190-202.

DOI: 10.1016/j.desal.2007.05.013

Google Scholar

[9] S.S. Madaeni, M.R. Eslamifard: J. Hazard. Mater., vol. 174(2010), pp.404-409.

Google Scholar

[10] M.D. Miller, J.E. Potts: Desalination, vol. 102 (1995) , pp.313-319.

Google Scholar

[11] P. Cuda, P. Pospísil, J. Tenglerová: Desalination, vol. 198 (2006), pp.41-46.

Google Scholar

[12] Q. Lei, W. Liang: J. Sustain. Dev., vol. 2 (2009).

Google Scholar

[13] T. Manth, J. Frenzel, A. van Vlerken: Desalination , vol. 118 (1998), pp.255-262.

DOI: 10.1016/s0011-9164(98)00140-4

Google Scholar

[14] W.F.J.M. Nooijen, P.A. de Boks, P.R. Vaal, W.B. Suratt: Desalination, vol. 118 (1998), pp.263-265.

DOI: 10.1016/s0011-9164(98)00143-x

Google Scholar

[15] H. K. Chai, A. W. Mohammad, S. Fatihah: Desalination, vol. 271 (2011), pp.178-186.

Google Scholar