Research on Double-Fed Motor Start Control Technology Based on Inverter

Article Preview

Abstract:

According to the doubly-fed motor starting control technology specialty, this paper proposes a new doubly-fed motor starting control method. Using detection circuit to monitor rotor voltage of doubly-fed motor in starting process, this method realizes the smooth transition from the asynchronous mode to doubly-fed model by controlling the transient output of inverter. On this basis, built control platform based on PLC and general converter, study the related experiment. Theoretical analysis and experimental results show that the proposed control method is feasible, and suitable for doubly-fed motor starting control process, so it has great practical value.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1297-1300

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Shoudao Huang, Biwu Hu, Honglin Ouyang and Lawu Zhou. Journal of Hunan University, 1998. 26(04): 67-70. (In Chinese).

Google Scholar

[2] Youquan Li and Yonglin Yan. Manufacturing automation, 2003, 22 (3): 55-57. (In Chinese).

Google Scholar

[3] Ji Zhang, Dong-chu Liao, Jian Pan and Jun Chen. Power Electronics, 2007. 02(2): 29-31. (In Chinese).

Google Scholar

[4] Siemens AG. Siemens Micromaster 440 Manual. [EB/OL]. [2003-12]. http: /www. Siemens. de/ micromaster.

Google Scholar

[5] Matteo Felice Iacchetti .M. S. Carmeli . Francesco Castelli Dezza . R. Perini. Electr Eng , 2010(91): 337–345. (In Chinese).

DOI: 10.1007/s00202-009-0144-8

Google Scholar