CFD Simulation of Natural Draught Cooling Tower Wind-Covering

Article Preview

Abstract:

Past experiences have shown that a local wind can considerably affect the performances of powerplant cooling towers and factory chimneys. In thermal powerplants, the performance of Rankin cycles would reduce if the temperature of its condenser increases. This issue is very important to powerplants located in countries with strong local winds. To remedy the mal-performance of a natural cooling tower in windy conditions, it is required to understand the physics of flow around cooling towers more clearly. One adverse physics is known as the wind covering problem which can drastically affect the natural draught through a cooling tower in windy conditions. In this paper, we focus on wind-covering problem and its adverse impact on a real natural draught cooling tower. Contrary to the past studies, we show that wind can generally affect either positively or negatively in cooling tower performances. Surprisingly, the positive and negative roles can simultaneously occur in most times. In this paper, we use computational fluid dynamics tool to quantify the positive and negative impacts of wind on natural draught flow through dry cooling towers.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

279-284

Citation:

Online since:

February 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] A. Du Preez, D.G. Kroger: Effect of wind on performance of a dry-cooling tower. Heat Recovery Systems and CHP, Vol. 13, No. 3 (1993), p.139.

DOI: 10.1016/0890-4332(93)90033-r

Google Scholar

[2] A. E. Conradie, D. G. Kroger: Performance evaluation of dry cooling systems for power plant applications. Applied Thermal Engineering, Vol. 16, No. 3 (1996), p.219.

DOI: 10.1016/1359-4311(95)00068-2

Google Scholar

[3] R. Al-Waked, M. Behnia: The performance of natural draft dry cooling towers under crosswind: CFD study. International Journal of Energy Research, Vol. 28, No. 2 (2004), p.147.

DOI: 10.1002/er.958

Google Scholar

[4] R. N. Meroney: CFD Prediction of Cooling Tower Drift Prepared. Journal of Wind Engineering and Industrial Aerodynamics, Vol. 94, No. 6 (2005), p.463.

DOI: 10.1016/j.jweia.2006.01.015

Google Scholar

[5] Z. Zhai, S. Fu: Improving cooling efficiency of dry-cooling towers under cross-wind conditions by using wind-break methods. Applied Thermal Engineering, Vol. 26, No. 10 (2006), p.1008.

DOI: 10.1016/j.applthermaleng.2005.10.016

Google Scholar

[6] M. Goodarzi: A proposed stack configuration for dry cooling tower to improve cooling efficiency under crosswind. Journal of Wind Engineering and Industrial Aerodynamics, Vol. 98, No. 12 (2010), p.858.

DOI: 10.1016/j.jweia.2010.08.004

Google Scholar

[7] M. Darbandi, H. Salemkar, A. Behrouzifar: Study of Wind Effect on Air Draft Reduction through Dry Cooling Tower and an Optimized Aero-Hydrodynamics Remedy to Overcome the Wind-Covering Effect, The 1st National Aerodynamics and Hydrodynamics Conference, Paper No. HAC2012-1080, Tehran, Iran, Oct. 16-17, 7 pages, 2012. (in Persian).

DOI: 10.4028/www.scientific.net/amm.307.279

Google Scholar