Analysis on Wind-Induced Vibration Dynamic Responses of Transmission Tower-Line System

Article Preview

Abstract:

Tower-line system of overhead transmission line are sensitive to wind. Therefore, dynamic effect of wind load should be taken into consideration, for instance, wind-induced vibration coefficient. There might be some errors in the calculation of the coefficient in accordance with ‘Load code for the design of building structures’, for its ignoring the irregular figure, scattered masses and coupling effect of tower-line system. Tower-line system is set up in virtual environment, with tower-line coupling considered, and research wind-induced vibration dynamic responses under Davenport wind speed spectrum. Random vibration theory was applied to calculate the coefficient. Whole tower was divided by hight, and calculated segment’s the wind-induced vibration coefficient seprately. Compare the coefficient from Load Code and random vibration theory, the latter with tower-line coupling effect and tower figure considered, is close to the actual.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

284-289

Citation:

Online since:

June 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yang J.B, Yang. F.L: Calculation of Wind-induced Dynamic Load of Transmission Tower Considering Coupled Vibration Affection of Conductors. Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific. 2010.3.

DOI: 10.1109/appeec.2010.5449026

Google Scholar

[2] Xie .Q, Zhang. Y and Li. J: Investigation on Tower Collapses of 500 kV Renshang 5237 Transmission Line Caused by Downburst. Power System Technology, Vol. 30 No. 10.

Google Scholar

[3] E.Savory, Gerard A.R. Parke and M. Zeinoddini: Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower.Engineering Structures (2001), Volume 23, 365-375.

DOI: 10.1016/s0141-0296(00)00045-6

Google Scholar

[4] A.Y. Shehata A.A. El Damatty and E. Savory: Finite element modeling of transmission line under downburst wind loading. Finite Elements in Analysis and Design. Vol.42, Issue 1, 2005(10), 71-89

DOI: 10.1016/j.finel.2005.05.005

Google Scholar

[5] Yang .J.B, Li. Z and Jiang. J. Dynamic Characteristics of Wind-induced Coupled Vibration Between Conductor and Tower of Transmission Line. Journal of Vibration, Measurement & Diagnosis. 2008(2):147-150.

Google Scholar