TCM Main Drives Revamping of Pangang

Article Preview

Abstract:

To study how to do, if adapting a Adjustable-Speed AC Drive System to control the equipment, now which is been controlled by the Adjustable-Speed DC Drive. According the operating parameters that requested by the production line of the Cold Rolling Mill of Pangang, the paper proves a revamping project. The project includes the selection of motor, the calculation of the electrical capacity of motor, and the selection of speed-control mode. Also the paper analyses and put forward to the revamping project of related supporting facilities.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

474-478

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Chuan Xia, Jun Yang, Qiuzhu Wang: Introduction of the continuous cold-rolling mill in Pangang, Steel Rolling, 1999.

Google Scholar

[2] ABB Switzorland Ltd,ACS6000 Medium Voltage Drives User S Manual[Z].2004.

Google Scholar

[3] Application guide for inverter drive (genenal-purpose inverter) [C]. The Japan Electrical Manufactureer's Association JEM-TR 148-1999 .

Google Scholar

[4] Van Der Broeck H.W., Skudenlny H.C. Analysis and Realizaion of a Pulsewidth Modulator Based on Voltage Space Vectors. IEEE Trans. IA, 1998,24(1).

Google Scholar