Analysis of Static Frequency Characteristics Based on Curve Fitting

Article Preview

Abstract:

Identification and calculation of static frequency characteristics is of great significance for power system to maintain its stability. In this paper, coefficient of static frequency characteristics is fitted by the least squares method. Frequency deviation restriction point under different capacitances is forecasted by the fitted trend of coefficient of static frequency characteristics. Moreover, the new method is simulated and its calculation error is also compared.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

602-607

Citation:

Online since:

July 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] CAI Bin. Power system frequency . Beijing: China Electric Power Press, (1998).

Google Scholar

[2] ZHANG Bin: Automatic generation control and a frequency modulation control system .China power press, (2005)1-7, 141-142.

Google Scholar

[3] XIONG Xiao-fu, ZHOU Shui-zhong, ZHOU Jia-qi:The low-frequency load shedding scheme when taking into account of the load frequency characteristics. Chinese Society for Electrical EngineeringVol.25 (2005),pp.48-51.

Google Scholar

[4] YU Da-ren,GUO Yu-feng: The online estimation of the grid frequency modulation ability.Chinese Society for Electrical EngineeringVol.24(2004), pp.72-76.

Google Scholar

[5] GE Rui, Dong Yu, lV Yue-chun:The inspiration of Europe "11.4" Blackouts and for the work of China's power grid operation . Power System TechnologyVol.31(2007), pp.1-6.

Google Scholar

[6] YIN Shui-hua, GUO Jian-bo, ZHAO Jian-jun: The United States and Canada "8.14" Blackouts preliminary analysis and lessons learned. Power System TechnologyVol.27(2003),pp.8-11.

Google Scholar

[7] Thalassinakis E J, Dialynas E N: A method for optimal a reserve allocation in isolated power systems incorporating an improved speed governor model. IEEE Trans on Power SystemsVol.22( 2007), pp.1629-1637.

DOI: 10.1109/tpwrs.2007.907953

Google Scholar

[8] BIAN Xing-ming, WEN Yuan-fang, LEI Qin:The comparison of power system frequency measurement algorithms.High voltage engineeringVol.32(2006),pp.111-114.

Google Scholar

[9] LUO Kai-ming, Li Xue, Sun Yong: Interconnected power system frequency response standard .Electric Power Automation EquipmentVol.28(2008),pp.111-113.

Google Scholar

[10] YU Da-ren,GUO Yu-feng, XU Ji-yu: The primary frequency stability of Generator set network operation . Chinese Society for Electrical EngineeringVol.20(2000),pp.59-63.

Google Scholar

[11] XI Jiang-hui, HU Ji-zhou, LING Wei-hong:Central China power system frequency static characteristic analysis. Central China powerVol.15(2002), pp.1-2, 7.

Google Scholar

[12] LV Xi-ming, LI Ming-yuan:Least squares curve fitting by MATLAB. Journal of Inner Mongolia national university (natural science edition)Vol.24( 2009),pp.125-127.

Google Scholar

[13] CHANG Xue-jiang, CHEN Ming, WANG Ming-sheng:Time series analysis.Beijing: higher education press(1993).

Google Scholar

[14] LIU Si-feng, GUO Tian-bang:Grey system theory and its application. Zhengzhou: Henan university press (1991).

Google Scholar