Performance Analysis and Improved Design on the Compliant Micro-Displacement Amplification Mechanism

Article Preview

Abstract:

By analysing the structural characteristics of the compliant micro-displacement amplification mechanism and the examples of the compliant micro-displacement amplification mechanisms with different link length and link angel, the combined compliant structure formed with flexure hinges and link is important component, the length and the angel of the link affect the thickness ratio and length ratio of the combined compliant structure, which plays a key role in amplification of the mechanism. The design method is proposed aiming at improving the amplification, which is used in the improved design of the compliant micro-displacement amplification mechanism. The amplification analysis of the improved mechanism is done, which proves the validity and rationality of the improved design .

You might also be interested in these eBooks

Info:

Periodical:

Pages:

83-88

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] S.B. Choi, S.S. Han, Y.M. Han B.S. Thompson A magnification device for precision mechanisms featuring piezo actuators and flexure hinges: Design and experimental validation[J]. Mechanism and Machine Theory. Vol. 42(2007), P. 1184.

DOI: 10.1016/j.mechmachtheory.2006.08.009

Google Scholar

[2] Kyung S Min1, Woo C Choi, Shin H Song, Eun J Hwang. Static and dynamic analysis of a Nano-positioning Flexure Hinge stage with a flexible lever mechanism[J]. Engineering Manufacture. Vol. 29(2005), P. 447.

DOI: 10.1243/095440505x32355

Google Scholar

[3] Nicolae Lobontiu. Analytical model of displacement amplification and stiffness optimization for a class of flexure-based compliant mechanisms[J]. Computers and Structures, 2003, 81: 2797-2810.

DOI: 10.1016/j.compstruc.2003.07.003

Google Scholar

[4] GAO J ZH, JIANG ZH D, ZHAO Y L. Design of MEMS-based compliant Micro-transmissions[J]. China Mechanical Engineering. Vol. 10(2006), P. 991.

Google Scholar

[5] WANG L T, ZHOU ZH P, MA ZH X. Analysis on magnification ability and loading capacity of Displacement magnification mechanism of flexible hinge. Journal of Machine Design. Vol. 7(2007), P. 11.

Google Scholar

[6] MA Hong-wen, YAO Shao-ming, Wang Li-quan, Zhi Zhong. Analysis of the displacement amplification ratio of bridge-type flexure hinge[J]. Sensors and Actuators. Vol. 132(2006), P. 730.

DOI: 10.1016/j.sna.2005.12.028

Google Scholar

[7] LIU Qing-ling, QIU Li-fang, WENG Hai-shan. Influence of the structure characteristics of a combined compliant structure on its deflection[J]. Journal of University of Science and Technology Beijing. Vol. 12(2010), p.1607.

Google Scholar

[8] LIU Qing-ling. Analysis and Simulation of the Compliant Symmetrical Micro-displacement Amplification Mechanism[J]. ENGINEERING MECHANICS. Vol. 6(2011), P. 231.

Google Scholar

[9] LI Y H, LI Q X, CHEN L Y, BAI L F. Study on design method of one-axis flexure hinge[J]. JT Tsinghua Univercity(Sci&Tech). Vol. 2(2002), P. 172.

Google Scholar

[10] Nicolae lobontiu. Compliant Mechanisms: Design of the Flexure Hinges[M]. New Work: 2003 by CRC Press LLC, Pages447-457.

Google Scholar

[11] LIU Qing-ling, WENG Hai-shan, QIU Li-fang. Compliances calculation and performance analysis of half hybrid flexure hinge[J]. Journal of Engineering Design. Vol. 4(2009),P. 276.

Google Scholar