Research on Cable Force Testing Method of Cable-Stayed Bridge Model Test

Article Preview

Abstract:

A new method of measurement of the cable force in cable-stayed bridge model test is introduced. Pressure ring sensor is used as the main component in this method and the tension of the stay cables can be measured real-time and in time. It is vertified that this method is exact and credible by model test and can be used in actual cable-stayed bridge. The static measurements for the test model are conducted. The testing results are compared with the numerical results of finite element model developed for the test model. A platform is established for the future researchs.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

1325-1330

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Yu Yi, Yu Tian-le, Le Han-yan. Fabrication of static force model for Jilin Lanqi Songhua river bridge at construction and completion stages[J]. World Bridge, 2008(1): 73-75, (in Chinese).

Google Scholar

[2] An Qun-hui, Liu Zi-ming. The Whole Model Test Study for JingZhou Changjiang River Highway Bridge[J]. Jounral of Bridge Construction, 2002(2): 15-18(in Chinese).

Google Scholar

[3] Li Jia-sheng, Yan Dong-huang, Tian Zhong-chu. The Accomplishing Introduction of Three-Tower Diagonal-Pull Bridge Model Test[J]. Jounral of Changsha Communications University, 1999, 15(3): 34-37(in Chinese).

Google Scholar

[4] Li Ya-fei, Yan Dong-huang, Tian Zhong-chu. Development and Manufacture of a Large Aluminum Test Model of Three Tower Cable-stayed Bridge[J]. Jounral of Changsha Communications University, 2000, 16(3): 37-41(in Chinese).

Google Scholar

[5] Liu Zhao-feng, Dai Xian-rong, Zhao Ren-da et. Measurement Result Analysis of Cable Forces in Model Experiment for Pylon of Cable-stayed Bridge with Twin-united Pylons and Twin Separete Girders [J]. Journal of Experimental Mechanics. 2009, 24(6): 573-578(in Chinese).

Google Scholar

[6] Ge Ji-ping, Li Hu-sheng. Experimental Study on Damage Identification of a Single Tower Cable-stayed Bridge Model With Flexibility Changing Ratio [J]. Joural of ShangHai Institute of Technology(Natural Sciences). 2010, 10(1): 38-43(in Chinese).

Google Scholar