Wind-Induced Dynamic Analysis and Construction Measures of Large Diameter Spherical Tank

Article Preview

Abstract:

It is easy for the bulky spherical tank to take place wind-induced buckling under wind load, combined with the Daqing region specific practical engineering, simulation analysis of spherical tank system with 15.7m under random wind loads has been carried out by using ANSYS finite element software. The author investigates the mechanical properties of spherical tanks with the actions of self-weight and wind load, and obtains the deformation and stress distribution law of the tank, pillars and drawbars, at last construction suggestions of spherical tank is given, and these can provide technical support for improving the actual design for large spherical tank.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

46-49

Citation:

Online since:

August 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] GB50009-2012: Code for design of Building Structure Load (China Building Industry Press, China 2012) (In Chinese).

Google Scholar

[2] Tao Liu and Fengpeng Yang: Proficient in ANSYS (Tsinghua University press, China 2002) (In Chinese).

Google Scholar

[3] Wenhua Hao: ANSYS Civil Engineering Application Examples (China Water Power Press, China 2005) (In Chinese).

Google Scholar

[4] GB50023-2003: Code for Design of Steel Structures (Science Press, China 2003) (In Chinese).

Google Scholar