Analysis on the Indoor Temperature in Households of Heating Metering with Work Mode
Abstract:
Based on the theory of the room heat balance ,this paper discussed the 24 hours indoor temperature with work mode ,and concluded that indoor temperature changed in three stages:steady period, cooling period and warming period .By testing the actual indoor temperature of different heating ways with work mode and comparing the cooling process of theory results with field measurements after the temperature control valve closed ,concluded that the theory results and field measurements were basically the same and if the temperature control valve was closed less than ten hours in the daytime, the largest reduction of indoor temperature were about 2 ~ 3 °C, and it wont reduce people's comfort with work mode when indoor or outdoor temperature was high.