Preliminary Study on the Comparable Flow Pattern between Stented and Non-Stented Aneurysm at Hypertension Condition

Article Preview

Abstract:

The presence of the vortex formation associated with high pressure gradient has aggravated the rupture at the aneurismal wall. In order to decrease the possibility of aneurysm to be rupture, device like wire-mesh called stent was inserted at the aneurysm bulge. This study was focused on investigates the hemodynamic factor especially pressure distribution toward the failure of the aneurismal wall. Computational fluid dynamics method has used to identify the influence of the hemodynamic factor at the aneurysm. The results of this study shown the slightly decrease of the pressure distribution after the insertion of the bare metallic stent (BMS). The results on non-stented aneurysm was depicted the strong vortex was dominated the entire region of aneurysm. The strength of the vortex also was seems very weak after the insertion of this stent. The flow visualization between stented and non-stented aneurysm has given a good features in deep understanding of hemodynamic effect on the aneurismal wall. From the observed, the insertion of the stent manages to reduce the stress that exerted to aneurismal wall as well as decreased the strength of the vortex formation.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

29-33

Citation:

Online since:

August 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] L. Zhonghua, Computational Analyses And Simulation Of Fluid-Structure Interaction Applied To Stented Abdominal Aortic Aneurysm, North Carolina State University, (2005).

Google Scholar

[2] Department of Health and Human service, Washington DC.

Google Scholar

[3] M.R. Abdul Kadir, I. Taib, N. Kamsah and K. Osman., Computational Analysis Of A Stented Abdominal Aortic Aneurysm Model, Proc. World Engineering Congress 2007, Penang, Malaysia, (2007).

Google Scholar

[4] H.M. Burt, and W.L. Hunter, Drug-eluting stents: A multidisciplinary success story, Advanced Drug Delivery Reviews, vol. 58, p.350– 357, (2006).

DOI: 10.1016/j.addr.2006.01.014

Google Scholar

[5] H.S. Borovetz, J.F. Burke, and T.M.S. Chang, Application of materials in medicine, biology and artificialorgans, Biomaterials Science, 2nd edition, Elsevier Academic Press, Boston, p.455–479, (2006).

Google Scholar

[6] G. Wilms, Endovascular Treatment of a Ruptured Paraclinoid Aneurysm of the Carotid Siphon Achieved Using Endovascular Stent and Endovascular Coil Placement, American Journal of Neuroradiology, vol. 21, pp.753-6, (2002).

Google Scholar

[7] E.T. Tayfun, S. Sunil, S. Matthew, and S. Brian, and Conklin1, Arterial fluid mechanics modeling with the stabilized space-time fluid-structure interaction technique, International Journal for Numerical Methods in Fluids, vol. 57, (no. 5), pp.601-629, (2008).

DOI: 10.1002/fld.1633

Google Scholar

[8] D.R. McClean, and N.L. Eigler, Stent design: implications for restenosis, Rev. Cardiovascular Medicine, vol. 3, pp. S16– S22, (2002).

Google Scholar

[9] C. Lally, F. Dolan, and P.J. Prendergast, Cardiovascular stent design and vessel stresses: a finite element analysis, Journal of Biomechanics, vol. 38, p.1574– 1581, (2005).

DOI: 10.1016/j.jbiomech.2004.07.022

Google Scholar

[10] Badreddin Giuma S. K, Kahar Osman and Mohamed Rafiq Abdul Kadir, Numerical Modeling of Fusiform Aneurysm with High and Normal Blood Pressure.

DOI: 10.1109/ams.2009.66

Google Scholar

[11] K.M. Khanafer et al. Modeling pulsatile flow in aortic aneurysms: Effect of non-Newtonian properties of blood, IOS Press, Biorheology 43 (2006) 661–679.

Google Scholar