A Mechatronic System for Interactive Scan Plan Prescription during Real-Time Cardiac Magnetic Resonance Imaging

Article Preview

Abstract:

Real-time magnetic resonance imaging (MRI) has many advantages as compared to traditional MRI and can be used for the visualization of dynamic moving cardiac structures and functions without cardiac gating, as the fast data acquisition apparently freezes the motion resulting from heart beating and lung breathing. During the past decades, fast pulse sequences and image reconstruction algorithms had been developed to improve the temporal resolution with acceptable spatial resolution. However, the bottle neck of current real-time MRI systems is the availability of a user-friendly prescription tool to allow a MRI technician to prescribe the 6-Degree-of-freedom imaging plane of the MRI system. To meet the needs of real-time MRI, a 3D input tool is developed which facilitates user interactive specification of the center position and plane orientation of the MRI imaging plane. This paper reports such a custom designed 6 degree-of-freedom 3D input device, which allows the user to interactively and intuitively manipulate the scan plane to direct the real-time imaging capability to a target position based on the visual feedback provided on the MRI console in the form of real-time MRI images

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2009-2012

Citation:

Online since:

September 2013

Authors:

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Huang Y and Hynynen K. MR-Guided Focused Ultrasound for Brain Ablation and Blood-Brain Barrier Disruption, Methods Mol Biol. 2011; 711: 579-93 (2011).

DOI: 10.1007/978-1-61737-992-5_30

Google Scholar

[2] Sussman, M.S. and Stainsby, J. A. and Robert, N. and Merchant,N. and Wright, G.A., Variable-Density Adaptive Imaging for High-Resolution Coronary ArteryMRI. Magnetic Resonance in Medicine, 48(5): 753-764. (2002).

DOI: 10.1002/mrm.10275

Google Scholar

[3] Detsky JS, Graham JJ, Vijayaraghavan R, Biswas L, Stainsby JA, Guttman MA, Wright GA, Dick AJ. Free-breathing, non gated real-time delayed enhancement MRI of myocardial infarcts: a comparison with conventional delayed enhancement, Journal of Magnetic Resonance Imaging. 2008 Sep; 28(3): 621-5.

DOI: 10.1002/jmri.21505

Google Scholar

[4] Kerr, A.B. and Pauly, J.M. and Hu, B.S. et al., Real-Time Interactive MRI on a Conventional Scanner, Magnetic Resonance in Medicine, Vol. 38, pp.355-367. (1997).

DOI: 10.1002/mrm.1910380303

Google Scholar

[5] Hardy, C. J. and Darrow, R. D. and Pauly, et al., Interactive Coronary MRI,. Magnetic Resonance in Medicine. Vol. 40 , pp.105-111 (1998).

Google Scholar

[6] Gardstrom, (2003) 3D Navigation for real-time MRI using six degrees of freedom interactive devices, Master thesis. Department of Science and Technology, Linkoping University, SE-601M. Sweden (2003).

Google Scholar

[7] Santos JM, Wright GA, Pauly JM. Flexible real-time magnetic resonance imaging, Conf. Proc. IEEE Eng. Med. Biol. Soc. 2: 1048-51 (2004).

Google Scholar

[8] Yi, D., Stainsby, J.A., Wright G. Intuitive and Efficient Control of Real-time MRI Scan Plane Using a Six-degree-of-freedom Hardware Plane Navigator,. Lecture Note of Computer Science (LNCS) Vol. 3217, pp.430-437 (2004).

DOI: 10.1007/978-3-540-30136-3_53

Google Scholar

[9] Radau, P., Hu, H., Sainsby, J., and Wright, G.A., Visualization System for Real-time Scan Plane and Catheter Navigation, Proceedings of 12th International Society of Magnetic Resonance in Medicine (ISMRM) conference. (2004).

Google Scholar

[10] Yi, D., Radau, P., Wright, G. Visualization and Surgical Path Planning Using a Cost-effective, Six Degree-of-freedom (6-DOF) Navigator,. Radiological Society of North America (RSNA) 2004. 90th Scientific Assembly and Annual Meeting (2004).

Google Scholar

[11] Yi, D., Wright, G. and Hu S.C. Device and Process for Manipulating Real and Virtual Objects in Three-dimensional Space. US patent 7, 466, 303 B2 (2008).

Google Scholar

[12] Wacker FK, Elgort D, Hillenbrand CM, Duerk JL, Lewin JS. The catheter-driven MRI scanner: a new approach to intravascular catheter tracking and imaging-parameter adjustment for interventional MRI, AJR Am J Roentgenol. Aug; 183(2): 391-5. (2004).

DOI: 10.2214/ajr.183.2.1830391

Google Scholar

[13] http: /www. gehealthcare. com/gecommunity/mri/mr_i/softapps/idrivepro. html.

Google Scholar