Study on Failure Trend of Single Shear Hydraulic Lift Platform Structure on Basis of Static Strength Analysis
Abstract:
To ensure the safe use of single shear hydraulic lift platform for processing and manufacturing railway vehicles. This paper analyzes the use conditions of single shear hydraulic lift platform, and makes a contact nonlinear finite element analysis on various typical use conditions. The positions of parts subject to danger can be found out through the results of static strength analysis, which finds out the weaknesses and prejudges the failure trend of parts, and which provides guidance for prejudging the faults in actual production and can prevent occurrence of accidents.
Info:
Periodical:
Pages:
544-548
Citation:
Online since:
November 2013