Rotor/Stator Interactions Study under Different Operating Condition in Axial Flow Pump
Abstract:
Rotor/Stator interaction in axial-flow pump is the main reason for pressure fluctuates, which impacts on operating security of axial flow pump. In order to study Rotor/Stator interaction phenomenon in axial flow pump, TJ04-ZL-02 hydraulic axial flow pump model is investigated under different operating condition by unsteady simulation based on k-ω turbulence model. Numerical results show that: different flow operating conditions will lead to different Rotor/Stator interaction phenomenon, and also different pressure fluctuation. Fluctuation amplitude in design operating condition is smaller than off design operating condition. So the study proves that pump running in the design operating conditions has important beneficial to the pump operational stability.
Info:
Periodical:
Pages:
168-172
Citation:
Online since:
October 2013
Authors:
Price:
Сopyright:
© 2014 Trans Tech Publications Ltd. All Rights Reserved
Share:
Citation: