A 2nd Order Delta-Sigma ADC for Pressure Sensor Interface

Article Preview

Abstract:

A second order delta-sigma analog-to-digital converter (ADC) including a bandgap reference, a bias circuit for sensor, and a digital filter for the interface of piezoresistive pressure sensor is presented. The proposed sensor interface circuit is designed to target a pressure range from 0 to 100 psi. The prototype sensor interface circuit is implemented in a 0.35 μm CMOS process. The single-loop, 1-bit, second-order delta-sigma ADC operates at OSR of 256 achieves 80.5 dB dynamic range (DR), 79.6 dB peak signal-to-noise ratio (SNR), and 74.4 dB peak signal-to-noise and distortion ratio (SNDR) over a signal bandwidth of 7.8 kHz with 3.3V supply while consuming 0.33mW including on-chip reference and bias current for sensor. (in Performance Summary: 0.95mW)

You might also be interested in these eBooks

Info:

Periodical:

Pages:

554-559

Citation:

Online since:

December 2013

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] B.J. Hosticka, Analog Circuits for Sensors, ESSCIRC, Sep, (2007).

Google Scholar

[2] R. Schreier, G. C. Temes, Understanding Delta-Sigma Data Converters, John Wiley & Sons, (2005).

Google Scholar

[3] A. A. Barlian, W. -T. Park, J. R. Mallon, A. J. Rastegar, and B. L. Pruitt, Review: Semiconductor Piezoresistance for Microsystems, Proc. IEEE, vol. 97, no. 3, p.513–552, (2009).

DOI: 10.1109/jproc.2009.2013612

Google Scholar