This paper adopt universal finite element calculation software to carry out force analysis for Shayubeigou prestressed reinforced concrete inverted siphon,computer is applied in analysis of prestressed reinforced concrete inverted siphon. Deducing variation law of the inverted siphons stress and displacement in construction process and operating process. The calculation results further shown design schemes rationality and safety. which provide reliable reference of design and construction for the prestressed reinforced concrete inverted siphon.