Seismic Performance Research of Viscous Dampers under Different Arrangement
Abstract:
This paper introduces a variety of viscous damper installation form, including brace, herringbone and cantilever wall installation. By an example, install the bracing form, herringbone installation form and type cantilever wall installation condition are compared, And to calculate the results of its damping effect has carried on the comparative study, The superiority of the cantilever wall type layout pattern is obtained.