Inactivation of Bioaerosol in Indoor Air by DC Corona Discharge

Article Preview

Abstract:

A novel DC corona discharge technology was applied on inactivation of bioaerosol in indoor air. A wide range of initial concentration of microorganisms (from 35×104 CFU/m3 to 3×106 CFU/m3) was tested to show excellent germicidal properties for its high inactivation efficiency. Over 99.997% of microbe into the reactor were inactivated at t=150s, EP 2kV/cm and initial population was 3.0×106 CFU/m3. The effects of active species produced by a DC corona discharge on the inactivation of a mixture of bacteria in flowing aerosol were proved. The active radicals like OH radical which acted on microbes in the way of direct oxidation were the most significant factors influencing the microbe inactive efficiency through the assessment of heat variety, ultraviolet emission and ozones generation. The active radicals generation in the process of sterilization can be simply controlled by regulating applied voltage before ozone generated. The results indicate that use DC corona discharge technology in the future application of indoor air decontamination.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2955-2958

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Bailis, R., M. Ezzati, D. M. Kammen. 2005. Mortality and greenhouse gas impacts of biomass and petroleum energy futures in Africa. Science. 308: 98-103.

DOI: 10.1126/science.1106881

Google Scholar

[2] Kalser, J. 2005. Critics questions proposed countermeasures agency. Science. 310: 755-755.

DOI: 10.1126/science.310.5749.755

Google Scholar

[3] Rao, C. S. 1991. Environmental pollution control engineering, pp.150-151. John Wiley & Sons Inc. New York.

Google Scholar

[4] Gadri, R. B., J. R. Roth and T. C. Montie. 2000. Sterilization and plasma processing of room temperature surfaces with a one atmosphere uniform glow discharge plasma OAUGDP, Surf. Coat. Tech. 131: 528-542.

DOI: 10.1016/s0257-8972(00)00803-3

Google Scholar

[5] Balakrishnana, P. A., A. Arunagiria and P.G. Raob. 2002. Ozone generation by silent electric discharge and its application in tertiary treatment of tannery effluent. J. Electrostat. 56: 77-86.

DOI: 10.1016/s0304-3886(02)00031-1

Google Scholar

[6] Chang, J. Sh. 2001. Recent development of plasma pollution control technology: a critical review. Sci. Tech. Adv. Mater. 2: 571-576.

Google Scholar

[7] Gibalov, V. and G. Pietsch. 2000. The development of dielectric barrier discharges in gaps and on surfaces. J. Phys. D: Appl. Phys. 33: 2618-2636.

DOI: 10.1088/0022-3727/33/20/315

Google Scholar