Optimization of the Installation of an Earth-to-Air Heat Exchanger and Detailed Design of a Dedicated Experimental Set-Up

Article Preview

Abstract:

Earth-to-Air Heat Exchangers (EAHE) represent a relatively simple technology that can be easily coupled with traditional HVAC systems as well as with hybrid systems in order to exploit the thermal capacity of the ground. The air is pre-heated in the cold season and pre-cooled in the warm season through the EAHE, thus smoothing the peak loads and reducing the primary energy consumption. The present paper presents an experimental set-up of an EAHE implemented in a rural area in the Sicily region, focusing on the selection of the type of soils and the characteristics of the monitoring system installed to collect information on the actual energy performance of the EAHE.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

2158-2161

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] C. Peretti, A. Zarrella, M. De Carli et al., The design and environmental evaluation of earth-to-air heat exchangers (EAHE). A literature review, Renewable and Sustainable Energy Reviews, vol. 28, p.107–116, (2013).

DOI: 10.1016/j.rser.2013.07.057

Google Scholar

[2] L. Pagliano, P. Zangheri, and S. Carlucci, A Way To Net Zero Energy Buildings For Italy: How The Earth-To-Air Heat Exchanger Could Contribute To Reach The Target In Warm Climates, in EuroSun 2010 – International Conference on Solar Heating, Cooling and Buildings, Graz, (2010).

DOI: 10.18086/eurosun.2010.07.14

Google Scholar

[3] S. Carlucci, P. Zangheri, and L. Pagliano, Achieving the Net Zero Energy target in Northern Italy: lessons learned from an existing Passivhaus with Earth-to-Air Heat Exchanger, Advanced Materials Research, vol. 689, pp.184-187, (2013).

DOI: 10.4028/www.scientific.net/amr.689.184

Google Scholar

[4] P. Zangheri, and L. Pagliano, Methodology for design and evaluation of zero energy buildings in mediterranean climate. Application to a Passivhaus with EAHE, in 3rd Passive And Low ENergy Cooling for the built environment Conference (PALENC 2010) and 5th European Conference on Energy Performance & Indoor Climate in Buildings (EPIC 2010), Rhodes Island (GR), 2010, pp.1-10.

DOI: 10.3763/aber.2009.0406

Google Scholar

[5] F. Ascione, L. Bellia, and F. Minichiello, Earth-to-air heat exchangers for Italian climates, Renewable Energy, vol. 36, no. 8, pp.2177-2188, AUG 2011, (2011).

DOI: 10.1016/j.renene.2011.01.013

Google Scholar

[6] M. Santamouris, Use of Earth to Air Heat Exchangers for Cooling, AIVC Ventilation Information Paper, vol. 11, p.8, (2006).

Google Scholar