The Acoustical Design of Conference Room Based on Speech Acoustic

Article Preview

Abstract:

Based on the the requirements of appropriate reverberation time for the speech acoustic-dominated conference room, which are stipulated in Code for architectural acoustical design of theater ,cinema and multi-use auditorium(GB/T 50356-2005), this paper is trying to redesign the conference room on the fifth floor of the college of architecture and civil engineering of Taiyuan University of Technology, on account of the problems found after the experimental measurement. And the author introduces Ecotect to simulate the redesigning plan, in the hope of providing reference to acoustical design for the speech acoustic-dominated conference room.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

127-130

Citation:

Online since:

January 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] P.X. Baimu: Autodesk Ecotect Analysis (version 1)(Electronic Industry Press, Peking 2011)(in Chinese).

Google Scholar

[2] X.T. Liu: Building physics (version 3)(China Construct Industrial Publisher, Peking 2010)(in Chinese).

Google Scholar

[3] S.X. Wu: The Design Principle of Architectural Acoustics (version1)(China Construct Industrial Publisher, Peking 2000)(in Chinese).

Google Scholar

[4] Code for architectural acoustical design of theater , cinema and multi-use auditorium(GB/T 50356-2005)(China Planning Press, Peking 2005)(in Chinese).

Google Scholar