Comprehensive Calculation of Winding Loss, Fluid and Temperature Field in Large Power Transformer

Article Preview

Abstract:

This paper has make a deep theoretical analysis and experimental research according to the load loss of large capacity transformer which included the loss component decomposition, the analysis of the oil flow cooling system performance and working condition, the stray loss and temperature rise of the winding area. We have done the following work on the background of the 1000kV power transformer: The winding area loss was calculated based on the weight coefficient method and field circuit coupling method; considering that the hydraulic loss of the transformer cooling system is nonlinear and the nonlinear operating characteristics of the oil flow pump, establishing the cooling oil-way mathematical model of the transformers non winding area, and analysis the working condition of the transformer cooling system. Establishing the transformer winding multi-physics coupling mathematical model and researching the transformer winding heat problem based on the nonlinear influence of the material. The error between the windings numerical calculation results and the loss, winding temperature rise meet requirements of the engineering analysis according to this method. The calculation in this paper has high precision, and it can be used in the structure optimization of the large transformer winding.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

3381-3384

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] LI Ji, LUO Longfu, XU Jiazhu.  Finite Element Analysis of the 3D Thermal Field of Main Transformer Oil Tank of Electric Locomotive[J], High Voltage Engineering, 2005, 31(8): 21-23.

Google Scholar

[2] DU Canxun, GUI Weihua, ZHOU Guanghou. Excessive Losses and Temperature Field Calculation of Stator Coil Bars in Air-cooled Large Hydro-generators[J]. Proceedings of the CSEE, 2012, 32(12): 111-119.

Google Scholar

[3] DING Shuye, GE Yunzhong, XU Dianguo, et al. Analysis of Fluid Field Inside a 1. 5 MW Doubly-fed Wind Generator[J]. Proceedings of the CSEE, 2012, 32 (21) 93-98.

Google Scholar

[4] Jacek Smolka, Andrzej J. Nowak. Experimental validation of the coupled fluid flow, heat transfer and electromagnetic numerical model of the medium-power dry-type electrical transformer[J]. International Journal of Thermal Sciences, 2008, 47(10): 1393-1410.

DOI: 10.1016/j.ijthermalsci.2007.11.004

Google Scholar

[5] Marina A. Tsili, Eleftherios I. Amoiralis, Antonios G. et al. Power transformer thermal analysis by using an advanced coupled 3D heat transfer and fluid flow FEM model[J]. International Journal of Thermal Sciences, 2012, 53: 188-201.

DOI: 10.1016/j.ijthermalsci.2011.10.010

Google Scholar