Overview of Discharges from Pumping Stations and the Consequent Water Pollution Characteristics in Central Shanghai, China

Article Preview

Abstract:

Discharges from pumping stations to rivers have become an important issue in central Shanghai. Based on the analysis of the contaminant concentrations and the volume of discharged water in central Shanghai over the past five years, this research has identified that the discharges from pumping stations to watercourse were composed of DWDs and WWDs. The total annual discharges were approximately 155 to 202 million cubic meters. The contaminant concentrations in the DWDs were close to those in the local domestic wastewater (DW), while the WWDs usually had higher concentrations of the contaminants than the local DW. In central Shanghai, the total contaminant discharges (2008 to 2012) from pumping stations were 72,900-95,700 t·a-1 for suspended solids (SS), 67,300-88,100 t·a-1 for chemical oxygen demand (COD), 20,200-27,100 t·a-1 for biochemical oxygen demand (BOD5), 2,000-3,000 t·a-1 for ammonia-nitrogen (NH3-N), 4,100-5,900 t·a-1 for total nitrogen (TN), and 800-1,300 t·a-1 for total phosphate (TP).

You might also be interested in these eBooks

Info:

Periodical:

Pages:

201-210

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Shanghai Environmental Protection Bureau. Report on environmental quality of shanghai pp.1982-2005. The Shanghai Environmental Monitoring Center, p.1983-(2006).

Google Scholar

[2] R.L. Ruan: Sustainable development of water resources and water environment in shanghai city. Water Resources Protection 1(2001) , pp.21-24.

Google Scholar

[3] Editorial committee of Shanghai Environment Yearbook. Shanghai Environment Yearbook 2011. Shanghai People's Publishing House (2011), pp.64-65.

Google Scholar

[4] E. Smith: Pollutant concentrations of stormwater and captured sediment in flood control sumps draining an urban watershed. Water Research 13(2001), pp.3117-3126.

DOI: 10.1016/s0043-1354(01)00008-2

Google Scholar

[5] M. Hua: Study on measurements of reducing rainfall overflow of municipal pump stations along suzhou creek. Ph. D dissertation, Tongji University, Shanghai (2005).

Google Scholar

[6] A.E. Barbosa, J.N. Fernandes and L.M. David: Key issues for sustainable urban stormwater management. Water Research 20 (2012), pp.6601-6608.

DOI: 10.1016/j.watres.2012.05.029

Google Scholar

[7] M.C. Gromaire, S. Garnaud, A. Gonzalez and G. Chebbo, Characterization of urban runoff pollution in Paris. Water Science and Technology 2(1999), pp.1-8.

DOI: 10.2166/wst.1999.0071

Google Scholar

[8] J.H. Lee, K.W. Bang: Characterization of urban stormwater runoff. Water Research 6, (2000), pp.1773-1780.

Google Scholar

[9] A. Bakera, R. Inverarityb, M. Charltonc and S. Richmondc: Detecting river pollution using fluorescence spectrophoto -metry: case studies from the Ouseburn, NE England. Environment pollution 1 (2003), pp.57-70.

DOI: 10.1016/s0269-7491(02)00408-6

Google Scholar

[10] P. Piro, M. Carbone, G. Garofalo and J. Sansalone: CSO treatment strategy based on constituent index relationships in a highly urbanised catchment. Water Science and Technology 12 (2007), pp.85-91.

DOI: 10.2166/wst.2007.758

Google Scholar

[11] H.Q. Zhang: Research on the Pollution Characteristics and Control Strategies for the Discharge of Disordered Drainage System. Ph. D dissertation, Tongji University, Shanghai (2009).

Google Scholar

[12] W. Zhang, A. A. Keller and D. Yue: Management of Urban Road Runoff Containing PAHs: Probabilistic Modeling and Its Application in Beijing, China. Journal of The American Water Resources Association 4(2009), pp.1009-1018.

DOI: 10.1111/j.1752-1688.2009.00343.x

Google Scholar

[13] J. Yi, J. Leshan, J. Tun: Higher water tariffs for less river pollution-Evidence from the Min River and Fuzhou City in China. China Economic Review 2(2011), pp.183-195.

DOI: 10.1016/j.chieco.2010.12.006

Google Scholar

[14] W. Zhang, W. Che and D.K. Liu: Characterization of runoff from various urban catchments at different spatial scales in Beijing, China.  Water Science And Technology 1(2012), pp.21-27.

DOI: 10.2166/wst.2012.156

Google Scholar

[15] Z.X. Xu, H.Q. Zhang and H.Z. Li: Analysis of the rainwater inflowing into the separated sewage system. 1st Environmental Pollution and Public Health (EPPH2009), Beijing, China(2009), pp.14-16.

Google Scholar

[16] P.T. Silbermann, J.M. Boccadoro and P.M. Ditto: Removal of illicit wastewater connections from the storm drainage system in Brookline, Massachusetts. Journal New England Water Environment Association 1(1998), pp.41-55.

Google Scholar

[17] C. Jewell: A systematic methodology for the identification and remediation of illicit connections. Journal New England Water Environment Association 2(2002), pp.120-135.

Google Scholar

[18] X.Y. Zhang, F.F. Lin, Wong and T. F. Mike: Identification of soil heavy metal sources from anthropogenic activities and pollution assessment of Fuyang County, China. Environmental Monitoring and Assessment 1-4(2009), pp.439-449.

DOI: 10.1007/s10661-008-0410-7

Google Scholar

[19] US EPA: Results of the national urban runoff program. US EPA(1983).

Google Scholar

[20] MEPC: Determination methods for examination of water and wastewater. Chinese Eviron. Sci. Press, Beijing(2002), pp.200-284.

Google Scholar