Abstract:

A new rectangular anti-icing structure with short pin fins is presented in this paper. Detailed experimental research is applied to discussing its heat transfer and enhancement characteristics. The results show that, heat transfer of this anti-icing structure enhances obviously, and the core factor for enhancement is the volume ratio occupied by pin fins in rectangular channel of anti-icing structure.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

518-522

Citation:

Online since:

February 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] Y. Bourgaulty, Z. Boutanios, W. G. Habashi, Three-dimensional Eulerian approach to droplet impingement simulation using FENSAP-ICE, Part1: Model, algorithm, and validation, Journal of Aircraft. 37 (2000) 95-103.

DOI: 10.2514/2.2566

Google Scholar

[2] F. Morency, H. Beaugendre, G. S. Baruzzi, et al, A comprehensive 3D simulation system for in-flight icing, AIAA-2001-2566. (2001).

DOI: 10.2514/6.2001-2566

Google Scholar

[3] R. Honsek, W. G. Habashi, Eulerian modeling of droplet impingement in the SLD regime of aircraft icing, AIAA-2006-465. (2006).

DOI: 10.2514/6.2006-465

Google Scholar

[4] A. Reehorst, J. Chung, M. Potapczuk, et al: An experimental and numerical study of icing effects on the performance and controllability of twin engine aircraft, AIAA-1999-0374. (1999).

DOI: 10.2514/6.1999-374

Google Scholar

[5] X. Q. Bu, G. P. Lin, J. Yu, Three-dimensional conjugate heat transfer simulation for the surface temperature of wing hot-air anti-icing system, Journal of Aerospace Power(Chinese). 24 (2009) 2495-2500.

Google Scholar

[6] E. Irani, K. M. Al-Khalil, Calibration and recent upgrades to the Cox icing wind tunnel, AIAA-2008-437. (2008).

DOI: 10.2514/6.2008-437

Google Scholar

[7] M. Papadakis, Parametric Investigation of a Bleed Air Ice Protection System, AIAA Aerospace Sciences Meeting and Exhibit. 44 (2006) 1-28.

DOI: 10.2514/6.2006-1013

Google Scholar

[8] F. Saeed, F. Morency, I. Paraschivoiu, Numerical Simulation of a Hot-Air Anti-king System, AIAA-2000-630. (2000).

DOI: 10.2514/6.2000-630

Google Scholar

[9] P. Planquart, G. V. Borre, J. M. Buchlin, Experimental and Numerical Optimization of a Wing Leading Edge Hot Air Anti-icing System, AIAA-2005-1277. (2005).

DOI: 10.2514/6.2005-1277

Google Scholar

[10] Y. D. Su, S. L. Liu, H. Z. Su, Investigation on Heat Transfer in Pin Fin Array, Journal of Aerospace Power(Chinese) , 112 (1999) 95-99.

Google Scholar

[11] H. Z. Su, Investigation on Heat Transfer in Pin Fin Array, Journal of Aerospace Power(Chinese). 12 (1997) 175-179.

Google Scholar