Effect of Helical Screw Tape Insertion on Heat Transfer and Pressure Drop Characteristics in a Horizontal Concentric Double Tube Heat Exchanger

Article Preview

Abstract:

In the present work, the effects of insertion of helical screw tape on heat transfer characteristics and pressure drop in a concentric double tube heat exchanger are experimentally investigated. The heat exchanger has the outer (steel) and inner (copper) tube diameters of 50 mm and 25 mm respectively. The helical screw tape of diameter 19 mm is inserted into the inner tube to increase turbulence which helped to increase the heat transfer rate. The hot water was flowed through the inner tube and cold water was flowed in annulus. The helical screw tape was inserted in 1/3rd length and full length of the tube. The experiments are based on Reynolds number at tube inlet, ranging from 10000 to 42855. The experimental results show that the average Nusselt numbers and friction factors are respectively, 1.41 and 2.08 times over the plain tube for 1/3rd length insert and 1.87 and 4.31 times over the plain tube for full length insert. Furthermore, the enhancement ratio of the helical screw tape varies between 1.03 and 1.17, 1.02 and 1.26 for 1/3rd length insert and full length insert, respectively.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

622-627

Citation:

Online since:

March 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] S. Eiamsa-ard, P. Promvonge, Enhancement of heat transfer in a tube with regularly -spaced helical tape swirl generators, Solar Energy 78 (2005) 483–494.

DOI: 10.1016/j.solener.2004.09.021

Google Scholar

[2] Sivashanmugam, S. Suresh, Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with helical screw-tape inserts, Applied Thermal Engineering 26 (2006) 1990–(1997).

DOI: 10.1016/j.applthermaleng.2006.01.008

Google Scholar

[3] Pongjet Promvonge, Somsak Pethkool, Monsak Pimsarn, Chinaruk Thianpong, Heat transfer augmentation in a helical-ribbed tube with double twisted tape inserts, International Communications in Heat and Mass Transfer 39 (2012) 953–959.

DOI: 10.1016/j.icheatmasstransfer.2012.05.015

Google Scholar

[4] S. Eiamsa-ard, P. Promvonge, Heat transfer characteristics in a tube fitted with helical screw-tape with/without core-rod inserts, International Communications in Heat and Mass Transfer 34 (2007) 176–185.

DOI: 10.1016/j.icheatmasstransfer.2006.10.006

Google Scholar

[5] Halit Bas, Veysel Ozceyhan, Heat transfer enhancement in a tube with twisted tape inserts placed separately from the tube wall, Experimental Thermal and Fluid Science 41 (2012) 51–58.

DOI: 10.1016/j.expthermflusci.2012.03.008

Google Scholar

[6] Smith Eiamsa-ard , Somsak Pethkool , Chinaruk Thianpong , Pongjet Promvonge , Turbulent heat transfer and pressure loss in a double pipe heat exchanger with louvered strip inserts, International Communications in Heat and Mass Transfer 35 (2008).

DOI: 10.1016/j.icheatmasstransfer.2007.07.003

Google Scholar