Effect of Rice Husk Ash Fineness on the Properties of Concrete

Article Preview

Abstract:

In the present research, the effect of rice husk ash fineness on the properties of concrete was studied. Eight different fineness grades of rice husk ash were examined. A rice husk ash dosage of 15% by weight of binder was used throughout the experiments. The water-to-binder ratio was 0.49 to produce concrete having target strength of 40MPa at 28 d. Workability, compressive strength and gas permeability tests were carried out to identify the properties of concrete. The results revealed that increasing the fineness of RHA by mechanical grinding was found to improve the workability of RHA blended cement concrete. In addition, the use of RHA3 with mean particle size of 9.52μm produces the concrete with good strength. Finally, significant improvement was observed in mixtures incorporating RHA in terms of permeability coefficient.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

203-207

Citation:

Online since:

June 2014

Export:

Price:

Permissions CCC:

Permissions PLS:

Сopyright:

© 2014 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] K. Ganesan, K. Rajagopal and K. Thangavel: Constr. Build. Mater Vol. 22 (2008), p.1675–1683.

Google Scholar

[2] M.R. Karim, M.F.M. Zain, M. Jamil and F.C. Lai: Constr. Build. Mater Vol. 49 (2013), p.894–902.

Google Scholar

[3] M. Jamil, A.B.M.A. Kaish, S.N. Raman and M.F.M. Zain: Constr. Build. Mater Vol. 47 (2013), p.588–593.

Google Scholar

[4] P.J. Ramadhansyah, A.W. Mahyun, M.Z.M. Salwa, B.H. Abu Bakar, M.A. Megat Johari and M.H. Wan Ibrahim. Thermal analysis and pozzolanic index of rice husk ash at different grinding time. Procedia Eng Vol. 50 (2012), pp.101-109.

Google Scholar

[5] W. Kroehong, T. Sinsiri, C. Jaturapitakkul and P. Chindaprasirt: Constr. Build. Mater Vol. 25 (2011), p.4095–4104.

Google Scholar

[6] C. Jaturapitakkul, J. Tangpagasit, S. Songmue and K. Kiattikomol: Constr. Build. Mater Vol. 25 (2011), p.4287–4293.

DOI: 10.1016/j.conbuildmat.2011.04.073

Google Scholar

[7] BS EN 12350-2: 2009. Testing fresh concreteSlump-test. British European Standard. London, United Kingdom.

Google Scholar

[8] B.H. Abu Bakar, P.J. Ramadhansyah and M.A. Megat Johari: Mag. Concrete. Res Vol. 63 (2011), pp.313-320.

Google Scholar

[9] E. Peris-Mora, J. Payá and J. Monzó: Cement. Concrete. Res Vol. 23 (1993), p.917–924.

DOI: 10.1016/0008-8846(93)90045-b

Google Scholar

[10] S-C. Pan, D-H. Tseng, C-C. Lee and C. Lee: Cement. Concrete. Res Vol. 33 (2003), p.1749–1754.

Google Scholar

[11] G.C. Cordeiro, R.D.T. Filho, L.M. Tavares, E. de Moraes Rego Fairbairn and S. Hempel: Cement. Concrete. Res Vol. 33 (2011), p.529–534.

Google Scholar

[12] S.T. Lee, H.Y. Moon, R.D. Hooton and J.P. Kim: Cement. Concrete. Res Vol. 35 (2005), p.1314–1323.

Google Scholar